42/56
M880 ALL EN 2.7.2.docx
Operating temperature range of H type receivers
-
25°C to +70 °C (-13°F to +158°F )
Operating temperature range of transmitters
-
25°C to +55 °C (-13°F to +131°F )
Storage temperature range
-
40°C to +85°C (-40°F to +185 °F)
Marking
CE, FCC, IC, ARIB
NOTE(
1
)
ISM Band
stands for
Industrial, Scientific and Medical
Band
12.3. Transmitter
Radio module specs.see § 11.1
CE Radio module
Standard commands
START,HORN,STOP(
1
)
Security KEY
Commands sequence that allow the
startup of remote control unit (could be
disabled)
Antenna
Integrated
Configuration and diagnostic interface
Radio/Computer(
2
)
Safety categories ISO13849-1
a)
STOP circuit
PLe Cat. 4
(ISO 13849-1:2006 6.2.7 architecture)
with
a 5A fuse protection
b)
JOYSTICK commands
up
to
PLd Cat. 3
(ISO 13849-1:2006 6.2.6 architecture)
c)
Toggle sw. and push btn commands
up to
PLc Cat. 2
(ISO 13849-1:2006 6.2.5 architecture)
d)
Toggle sw. and push btn commands
up
to
PLc Cat. 1
(ISO 13849-1:2006 6.2.4 architecture)
Status indicator and error LEDs
-
Green: power on
-
Yellow: diagnostic
-
Blue: LINK Status
Commands / Outputs
56 Max (
3
)
Numbers of panel indicators
16 Max (
4
)
Number of ON/OFF commands
56 Max (
5
)
Number of analog commands
16 (19) Max (
5
)
Max Number of UMFS commands up to PL d, Cat. 3
16 (
6
)
(ISO 13849-1:2006 6.2.6
architecture)
Display
Graphic backlight LCD
a) 102x64 pixels monochromatic
b) 128x64 pixels monochromatic
c) 160x64 pixels monochromatic
d) QVGA 3,5” color TFT (optional)
Beeper
internal Buzzer
Backlit panel
optional
Serial Lines
-
RS232 o RS485
-
CAN
OPTIONS
-
Wired control cable
-
Lean-angle control