7.19. M880 LAC Version (PCB130)
Options on
request
SIMBOL
DESCRIPTION
24..240 VAC
Power supply input
GND
Ground connection
F1
Power Supply fuse T4A L250V
F5
Protection fuse 5VDC T1A L250V
SAFETY-ENABLE
Safety-Enable relay
E-STOP A
E-STOP A relay
E-STOP B
E-STOP B relay
F2 , F3 , F4
Protection fuses E-STOP and SAFETY_ENABLE T5A L250V
START
Output relay N.O.
HORN
Output relay N.O. / N.C. HORN command
TIMED - RELAY
N.O. / N.C. relay
CAN-H
CAN-H Line
CAN-L
CAN-L Line
D0, ,D7
Digital Inputs 0..20V
AIN0,..,AIN3
Analog Inputs 0..10VDC
SERIAL
CONNECTION
CABLE
J2-2
RS485 DATA +
J2-3
RS485 DATA –
J2-4 +12
Auxiliary power supply 12VDC Imax = 500mA
J2-1 GND
Ground connection