COMBI 200: use and maintenance
___________________________________________________________________________________________________________________
5
$SSHQGL[
The appendix contains the diagrams for the various units present in the
machine and the reference drawings. This section also contains the
documentation for the components installed in the machine and referred to in
the manual.
:LULQJGLDJUDPV
For wiring, the operator must consult the diagrams below
,
S1
Control switch
C1
Capacitor
X1
Disk motor connector
PE
Overload line conductor
N
Neutral line conductor
L1
Phase line conductor
M1
Disk motor
M2
Pump motor
Fig.5.1
3UREOHPVFDXVHVVROXWLRQV
:$51,1*$OOWKHPDLQWHQDQFHRSHUDWLRQVPXVWEHFDUULHGRXWZKHQWKHPDFKLQHKDVEHHQVWRSSHGE\WXUQLQJWKHVHOHFWRUWR³´DQG
GLVFRQQHFWLQJWKHSRZHUVXSSO\
3UREOHP
&DXVH
6ROXWLRQ
When the start switch is pressed, the motor
does not start
−
No mains voltage.
−
The plug and socket are not connected
properly.
−
The power supply cable is disconnected
from the cabinet.
−
An electric wire inside the motor terminal
board is disconnected.
−
An electric wire inside the cabinet is
disconnected.
−
The mains switch is faulty.
−
Check the mains.
−
Reset the correct connection.
−
Replace the cable.
−
Contact an electrician for assistance.
−
Contact an electrician for assistance.
−
Change the switch.
No cooling water for the disk.
−
Consult machine cleaning, section 4.2 ,and tank cleaning, section 4.5
The disk does not cut.
−
Incorrect disk rotation direction.
−
Worn
disk.
−
Dismantle the disk and reposition it in the
direction indicated on the disk label.
−
Fit a new disk.