© 2016 imc Meßsysteme GmbH
imc CANSAS - Getting Started, Doc. Rev. 2.0 R1 - 2016-05-24
43
Signal connection
3.3.2 Modules with DSUB-9 connectors
3.3.2.1 CANSAS-K-INC4
DSUB-9 Pin
CON1
CON2
CON3
CON4
1
+IN1X
+IN2X
+IN3X
+IN4X
6
-IN1X
-IN2X
-IN3X
-IN4X
2
+IN1Y
+IN2Y
+IN3Y
+IN4Y
7
-IN1Y
-IN2Y
-IN3Y
-IN4Y
3
+INDEX
2
+INDEX
+INDEX
+INDEX
8
-INDEX
-INDEX
-INDEX
-INDEX
4
NC
NC
NC
NC
9
GND
GND
GND
GND
5
+5V
+5V
+5V
+5V
2
The incremental counter inputs have a common index track,
which is connected in parallel to the other inputs in each DSUB.
3.3.3 Modules with ITT VEAM
CAN/L-UNI8
CAN/L-CI8-V
CAN/L-CI8-V-SUPPLY
1050051
1050293
1050364
Round plugs ITT-VEAM (MIL-C-26482)
ITT VEAM
-UNI8
-L-CI8-V-(SUPPLY*)
A
+IN
+IN
B
-IN
-IN
C
+SUPPLY
(+SUPPLY)
D
-SUPPLY
GND (-SUPPLY)
E
TEDS
TEDS (OneWire)
F
SENSE/
RTD current source
I_PT (RTD
current source)
G
quarter bridge completion, Sense-lead
for RTD 3-wire connector
+I
(positiver Messeingang für Strommessung)
* - Sensor supply voltages available with optional sensor supply module
imc CANSAS -L-DO8R-V, -L-DI16-V, -L-DAC8-V, -L-PWM8-V
ITT VEAM
PIN
-L-DO8R-V
-L-DI16-V
-L-DAC8-V
L-PWM8-V
A
IN
+IN
PWM Open Drain
B
ON
-IN
C
OFF
OUT
Vcc
D
GND
GND
E
F
PWM TTL
G
CHASSIS
CHASSIS
CHASSIS
CHASSIS