Prior to power-up, set the jumper for the correct
Remote/Local
configuration. Place a
jumper on pins
1
and
2
to set the module for
Remote
control, or pins
2
and
3
to set the
module for
Local
control.
Figure 2-2
Jumper
CJ3/CJS3
for Remote and Local Control
The
Local
setting locks out external control panels and allows card-edge control only;
remote software applications can monitor, but not control the module. The
Remote
setting
allows either remote or local (card-edge) configuration, operation, and monitoring.
At the rear of the front module, Jumper
CJ2
is factory-set and should not be modified.
Maximum Frame Power Ratings
AES modules operate only in fan-cooled FR6822
+
QXFE frames, or FR6822
+
F
frames containing a 6800+ETH module, subject to the limitations shown in
Table 2-1
.
CAUTION: To maintain proper air flow and internal frame temperature, ensure that
the front panel is closed at all times and that the fan module is fully operational.
Pins: 3 2
1
Table 2-1
Maximum Allowable Frame Power Ratings
Frame Type
Max. Frame
Power
Dissipation
Number of
Usable
Slots*
Max. Power
Dissipation
Per Slot
FR6822
+
QXFE frame
F frame containing a
6800+ETH module (v. 4.8 or
higher)
120W
20
6 W
*Each AES module requires two slots; a frame can accommodate a maximum of ten AES
modules.