Chapter 2
Installation and Operation
16
AES Control Parameters
Note:
The sequence of options listed in the
Value/Range
column mirrors the sequence
achieved when you move the Navigation Toggle switch up.
The On/Off combinations of the control LEDs on the card edge indicate the active bank
number. See
Changing Parameter Settings
on page 8 for more information.
Bold
options are default settings for the parameter. Rows of the table that are shown in grey
indicate read-only parameters.
Parameter List
Table 2-7
ACO6800
+
AESD Parameters
Group
Parameter Name
Bank,
Sw
itc
h
Function
Options
General
Serial Number [RO]
Provides a readout of the module’s
serial number
Product Type [RO]
Displays the current module type
AES+CD
AES+CDL
AES+BD
BM Type [RO]
Indicates the type of back module
connected to the front module
CD
CDL
BD
CD (Mismatch)
CDL (Mismatch)
BD (Mismatch)
Factory Recall
0,F
Resets all parameters as default
value
--- (default)
Recall
Soft Reboot
0, E
Reboots the module
No
Yes
Audio Configuration > Work Mode
DA Work Mode
Sets the distribution amplifier work
mode
1x8 Mode
2x4 Mode
Audio Configuration > Switch Settings
AES A and AES B
Output Source [RO]
Displays the current 2X4 AES A or
AES B output source
Input A
Input B
AES A and AES B Alarm
Switch Level
1, 4
1, 7
Sets the level for the 2X4 AES A
and AES B alarm auto switch
1 to 10 (
6
)