AES
Installation and Operation Manual
15
Sample Scenario Two: Chain of Events
Table 2-6
Sample Scenario Two: Chain of Events
Event
Result
1. At the start, input A and
input B are both present
Output is A (A is the primary channel in 1x8 mode)
2. Input A is lost
Output is A (alarm is not yet triggered; waiting for one
second trigger condition).
3. One second pass
Output is B (alarm is triggered).
4. Input A is present
Output is B (Non-resetting mode)
5. Input B is lost
Output is B (Non-resetting Protection is Stay with B)
6. A user sets AES Alarm
Reset to On
Output is A (Alarm Reset change the output back to
primary channel A)