CMN-91
Installation and Operation Manual
Operation
© 2016 Imagine Communications Corp. Proprietary and Confidential.
Revision D | Page 96
Relative timing of the inputs is compliant with SMPTE RP168.
Figure 53:
Timing Display Diagram
Field
Identifier
Field Information
Nomenclature
1
Selected reference
Displays the selected reference as REF: X where X is ExtREF or LTC;
the REF is selected in the Timing Setup menu; also indicates
reference format
2
Test
Indicates the input that is being measured against the selected
reference in Field Identifier 1; also displays the input's line
rate/frame rate (shown in as 525/59.94); selected in the Video
Setup menu
3
VERT (Vertical)
The offset line in full-video lines between the reference and the
displayed video
Displays the Vertical Error Measurement as VERT: xxx Line(s),
where xxx is the measured difference between the reference and
the test input alignment of the vertical timing (sync/TRS) in lines
4
HORZ (Horizontal)
The offset time in microseconds between the reference and the
displayed video
Displays the Horizontal Error Measurement as HORZ: yy.yyy µs,
where yy.yyy is the measured difference between the reference
and the test input alignment of the horizontal timing (sync/TRS)