background image

ORDERING REPLACEMENT PARTS

To order replacement parts, simply call our Customer Service Department toll-free at SEARS 1-800-4MYHOME
(469-4663), or SEARS 1-877-LEFOYER (533-6937) 24 hours a day. To help us assist you, please be prepared
to give the following information when calling:

• The MODEL NUMBER of the product (831.105021)

• The NAME of the product (IMAGE

®

RENEW 510 hydrotherapy spa)

• The SERIAL NUMBER of the product (see the front cover of this manual)

• The KEY NUMBER and DESCRIPTION of the desired part(s) (see the PART LIST and the EXPLODED DRAW-

ING on pages 20 and 21).

Part No. 171083 R1200A

Printed in USA © 2000 ICON Health & Fitness, Inc.

LIMITED FIVE YEAR MASSAGE SPA WARRANTY

ICON Health & Fitness, Inc. (ICON), warrants this product to be free from defects in workmanship and
material, under normal use and service conditions, for a period of ninety (90) days from the date of pur-
chase. ICON extends a limited five (5) year warranty on the spa shell structure. ICON also extends a lim-
ited two (2) year warranty on the pump and motor. This warranty extends only to the original purchaser.
ICON's obligation under this warranty is limited to replacing or repairing, at ICON's option, the product
through one of its authorized service centers. All repairs for which warranty claims are made must be pre-
authorized by ICON. This warranty does not extend to any product or damage to a product caused by or
attributable to freight damage, abuse, misuse, improper or abnormal usage, or repairs not provided by
ICON authorized service personnel, to products used for commercial or rental purposes, or to products
used as store display models. Specifically excluded are damages caused by or attributable to the follow-
ing incidents: any damage to the wood exterior resulting from improper maintenance, or any damage to
the wood or tile exterior attributable to freight mishandling; damage resulting from improper winterization;
damage to the spa shell resulting from improper chemical treatment, damage to the spa shell resulting
from exposure to extreme temperatures, or damage to the spa shell resulting from exposure to direct sun-
light and ultraviolet rays while the spa is empty; damage to the pump, motor, plumbing, and components
due to improper maintenance, chemical treatment, or exposure; damage resulting from failure to proper-
ly follow user’s manual installation, operating, or maintenance instructions. Also excluded are consumable
components, including but not restricted to headrests, filter cartridges, and light bulbs. No other warranty
beyond that specifically set forth above is authorized by ICON.

ICON is not responsible or liable for indirect, special or consequential damages arising out of or in con-
nection with the use or performance of the product or damages with respect to any economic loss, loss
of or damage to property including water damage, loss of revenues or profits, loss of enjoyment or use,
costs of removal, installation or other consequential damages of whatsoever nature. Some states do not
allow the exclusion or limitation of incidental or consequential damages. Accordingly, the above limitation
may not apply to you.

The warranty extended hereunder is in lieu of any and all other warranties and any implied warranties of
merchantability or fitness for a particular purpose is limited in its scope and duration to the terms set forth
herein.  Some states do not allow limitations on how long an implied warranty lasts. Accordingly, the above
limitation may not apply to you.

This warranty gives you specific legal rights. You may also have other rights which vary from state to state.

ICON HEALTH & FITNESS, INC., 1500 S. 1000 W., LOGAN, UT 84321-9813

All manuals and user guides at all-guides.com

Summary of Contents for 831.105021

Page 1: ...before using this equipment Save this manual for future reference USER S MANUAL www imagefitness com Visit our website at To schedule repair service or to purchase parts call SEARS toll free at 1 800...

Page 2: ...ERAPY SPA 7 SET UP AND ASSEMBLY 8 USING THE HYDROTHERAPY SPA 10 MAINTENANCE 14 TROUBLE SHOOTING 18 PART LIST 20 EXPLODED DRAWING 21 ORDERING REPLACEMENT PARTS Back Cover LIMITED WARRANTY Back Cover 2...

Page 3: ...s high as 150 F 65 C in a matter of minutes if exposed to the sun while it is empty These high temperatures can cause significant damage such as blis tering of the shell surface and warping of the spa...

Page 4: ...38 C may be injurious to your health If you plan to remain in the hydrotherapy spa for more than 10 to 15 minutes lower the temperature to 100 F 38 C or below Lower temperatures are also recommended f...

Page 5: ...mum Breaker Fuse 40 Amps 39 A green terminal or a terminalmarked G GR Ground Grounding or with the symbol is located inside the supply terminal box or compartment To reduce the risk of electric shock...

Page 6: ...the specialized treatment you need to feel your best For your safety and benefit read this manual care fully before using the RENEW 510 If you have addi tional questions please call our Customer Serv...

Page 7: ...that is built flush with the top of the spa provided you leave access to the motor for ser vice 8 Make sure to consider such factors as aesthetics or privacy that may affect the safety or enjoyment o...

Page 8: ...the information on the previous two pages Remove the four screws from the access cover on the console side of the spa Remove the access cover by sliding it down and then pulling the bottom of it away...

Page 9: ...ply a little soap or wax to the screw threads Attach the other three Buckles 2 to the wood panels in the same way 18 Spa Spa Strap 2 2 1 Strap Latch 5 Before using the spa follow the instructions on p...

Page 10: ...ESTING AND TREATING THE WATER The hydrotherapy spa comes with a starter chemical pack for maintaining the water in the spa Disregard the directions on the individual packages of QUICK pHix It DOWN and...

Page 11: ...k Note Each thera jet can be shut off by being pressed in and turned back on by being pulled out The filter C can be removed for cleaning and replacement see page 17 The suction vent D located near th...

Page 12: ...ur filter cycle time Then press the jet button again If the filter cycle time is not changed it will default to 2 hours Jet Button Turns the spa jets on and off If the but ton is pressed once the spa...

Page 13: ...G Spa heat speeds up the effect of alcohol drugs or medicine and can cause unconsciousness Immediately leave spa if uncomfortable or sleepy DURING PREGNANCY SOAKING IN HOT WATER MAY CAUSE DAMAGE TO TH...

Page 14: ...sealants work best in your climate CLEANING THE SPA SHELL The spa shell should be cleaned with a mild soap solution Do not use solvents The spa should always be clean and dry before being moved or st...

Page 15: ...level in the water will begin to cor rode the metal parts in the spa jet unit Also the sani tation agents in the water will not be effective if the pH level is not properly maintained Damage caused b...

Page 16: ...by turning the knob counterclock wise The water will begin to drain 6 When the spa is empty close the valve and remove the garden hose Return the drainage hose to the clip and replace the access cove...

Page 17: ...asket towards you until it snaps free 4 Lift the basket out of the filter housing by pulling on the handle on the far side and turning the bas ket towards you 5 Clean the basket by spraying it with a...

Page 18: ...ke sure that the hydrotherapy spa is fully covered with the spa cover The spa cover must be tight for the water to heat Set the air control to low Set the temperature to the desired setting The water...

Page 19: ...t unit tight en the clamp or replace the damaged seal 10 SYMPTOM THE SPA CONTINUES TO RUN AFTER IT HAS BEEN SHUT OFF a To turn the spa jets on press the Pump button once To turn the spa jets off press...

Page 20: ...22 1 Basket 23 10 8 x 1 1 2 Screw 24 1 Filter Door 25 2 Cover Screw 26 2 Suction Cover 27 3 Rubber Washer 28 1 O ring 29 1 Drain Plug 30 1 Hose Washer 31 1 Sensor Fitting Assembly 32 1 Diverter Valve...

Page 21: ...21 EXPLODED DRAWING Model No 831 105021 R1200A 4 28 5 13 29 12 3 14 9 16 16 3 9 15 1 2 2 7 17 18 26 25 20 20 31 20 27 All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 22: ...22 NOTES All manuals and user guides at all guides com...

Page 23: ...23 NOTES All manuals and user guides at all guides com...

Page 24: ...from improper maintenance or any damage to the wood or tile exterior attributable to freight mishandling damage resulting from improper winterization damage to the spa shell resulting from improper c...

Reviews: