background image

15

Additional chemicals can be purchased at a pool and
spa supply store.

CAUTION: The chemicals used to maintain the pH
balance of the water and to sanitize the water can
be dangerous. Always follow these basic guide-
lines when handling the chemicals:
1. Always read and follow the directions on the

label, unless directed otherwise.

2. Never mix different chemicals.
3. Do not exceed the recommended amounts of

chemicals—follow the directions on the label
closely.

4. Keep all chemicals out of the reach of children

and pets.

5. Keep all containers closed tightly when not in

use.

6. Never add water to the chemicals—always add

the chemicals to the water as directed.

7. Always store chemicals in a cool, dry place.

MAINTAINING THE PROPER PH BALANCE

The pH factor is a measure of relative acidity or alka-
linity in the water. It is measured on a scale of 1 to 14.
Pure water has a value of 7, which is neutral. Any
value above 7 is alkaline, and any value below 7 is
acidic. You should maintain a slightly alkaline pH
level, between 7.2 and 7.8, in the hydrotherapy spa. 

Severe problems can occur when the pH balance is
not maintained within this range. If the pH level
exceeds 7.8, dissolved minerals can build-up and clog
the plumbing in the spa jet unit. If the pH level falls
below 7.2, the acid level in the water will begin to cor-
rode the metal parts in the spa jet unit. Also, the sani-
tation agents in the water will not be effective if the pH
level is not properly maintained. Damage caused by
improper pH levels is not covered under the warranty.

To maintain the proper pH level, you should test the
pH of the water regularly, using the included pH test
kit. The pH reading should be between 7.2 and 7.8. If
the level is too low, add a pH increaser (usually soda
ash). If the level is too high, add a pH reducer (usually
sodium bisulfate). Test the water again after five min-
utes. See the instructions with your pH test kit for addi-
tional information about testing and adjusting the pH.

ATTACHING AND REMOVING THE ACCESS COVER

To locate the access cover, refer to the drawing on
page 6. Turn off the power to the spa. To remove the
access cover, first remove the four access cover
screws. Slide the access cover down and then pull
the bottom of it away from the spa. Be careful not to
damage the spa shell as you remove the cover.

If the spa will be stored for any period of time, place
the power cord inside the spa before re-attaching the
access cover.

To reattach the access cover, insert the top of the
cover under the edge of the spa shell. Slide the cover
up until the bottom of the cover clears the trim along
the bottom of the spa. Slide the cover into place and
re-attach it with the two access cover screws.

Screws 

Access

Panel 

All manuals and user guides at all-guides.com

Summary of Contents for 831.105021

Page 1: ...before using this equipment Save this manual for future reference USER S MANUAL www imagefitness com Visit our website at To schedule repair service or to purchase parts call SEARS toll free at 1 800...

Page 2: ...ERAPY SPA 7 SET UP AND ASSEMBLY 8 USING THE HYDROTHERAPY SPA 10 MAINTENANCE 14 TROUBLE SHOOTING 18 PART LIST 20 EXPLODED DRAWING 21 ORDERING REPLACEMENT PARTS Back Cover LIMITED WARRANTY Back Cover 2...

Page 3: ...s high as 150 F 65 C in a matter of minutes if exposed to the sun while it is empty These high temperatures can cause significant damage such as blis tering of the shell surface and warping of the spa...

Page 4: ...38 C may be injurious to your health If you plan to remain in the hydrotherapy spa for more than 10 to 15 minutes lower the temperature to 100 F 38 C or below Lower temperatures are also recommended f...

Page 5: ...mum Breaker Fuse 40 Amps 39 A green terminal or a terminalmarked G GR Ground Grounding or with the symbol is located inside the supply terminal box or compartment To reduce the risk of electric shock...

Page 6: ...the specialized treatment you need to feel your best For your safety and benefit read this manual care fully before using the RENEW 510 If you have addi tional questions please call our Customer Serv...

Page 7: ...that is built flush with the top of the spa provided you leave access to the motor for ser vice 8 Make sure to consider such factors as aesthetics or privacy that may affect the safety or enjoyment o...

Page 8: ...the information on the previous two pages Remove the four screws from the access cover on the console side of the spa Remove the access cover by sliding it down and then pulling the bottom of it away...

Page 9: ...ply a little soap or wax to the screw threads Attach the other three Buckles 2 to the wood panels in the same way 18 Spa Spa Strap 2 2 1 Strap Latch 5 Before using the spa follow the instructions on p...

Page 10: ...ESTING AND TREATING THE WATER The hydrotherapy spa comes with a starter chemical pack for maintaining the water in the spa Disregard the directions on the individual packages of QUICK pHix It DOWN and...

Page 11: ...k Note Each thera jet can be shut off by being pressed in and turned back on by being pulled out The filter C can be removed for cleaning and replacement see page 17 The suction vent D located near th...

Page 12: ...ur filter cycle time Then press the jet button again If the filter cycle time is not changed it will default to 2 hours Jet Button Turns the spa jets on and off If the but ton is pressed once the spa...

Page 13: ...G Spa heat speeds up the effect of alcohol drugs or medicine and can cause unconsciousness Immediately leave spa if uncomfortable or sleepy DURING PREGNANCY SOAKING IN HOT WATER MAY CAUSE DAMAGE TO TH...

Page 14: ...sealants work best in your climate CLEANING THE SPA SHELL The spa shell should be cleaned with a mild soap solution Do not use solvents The spa should always be clean and dry before being moved or st...

Page 15: ...level in the water will begin to cor rode the metal parts in the spa jet unit Also the sani tation agents in the water will not be effective if the pH level is not properly maintained Damage caused b...

Page 16: ...by turning the knob counterclock wise The water will begin to drain 6 When the spa is empty close the valve and remove the garden hose Return the drainage hose to the clip and replace the access cove...

Page 17: ...asket towards you until it snaps free 4 Lift the basket out of the filter housing by pulling on the handle on the far side and turning the bas ket towards you 5 Clean the basket by spraying it with a...

Page 18: ...ke sure that the hydrotherapy spa is fully covered with the spa cover The spa cover must be tight for the water to heat Set the air control to low Set the temperature to the desired setting The water...

Page 19: ...t unit tight en the clamp or replace the damaged seal 10 SYMPTOM THE SPA CONTINUES TO RUN AFTER IT HAS BEEN SHUT OFF a To turn the spa jets on press the Pump button once To turn the spa jets off press...

Page 20: ...22 1 Basket 23 10 8 x 1 1 2 Screw 24 1 Filter Door 25 2 Cover Screw 26 2 Suction Cover 27 3 Rubber Washer 28 1 O ring 29 1 Drain Plug 30 1 Hose Washer 31 1 Sensor Fitting Assembly 32 1 Diverter Valve...

Page 21: ...21 EXPLODED DRAWING Model No 831 105021 R1200A 4 28 5 13 29 12 3 14 9 16 16 3 9 15 1 2 2 7 17 18 26 25 20 20 31 20 27 All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 22: ...22 NOTES All manuals and user guides at all guides com...

Page 23: ...23 NOTES All manuals and user guides at all guides com...

Page 24: ...from improper maintenance or any damage to the wood or tile exterior attributable to freight mishandling damage resulting from improper winterization damage to the spa shell resulting from improper c...