background image

6

27

HOW TO PUT ON THE HEART RATE MONITOR  

The heart rate monitor consists of two components:
the chest strap and the sensor unit (see the drawing
below). Insert the tab on one end of the chest strap
through the hole in one end of the sensor unit. Press
the end of the sensor unit under the buckle on the chest
strap. The tab should be almost flush with the front of
the sensor unit.

Next, wrap the
heart rate moni-
tor around your
chest and attach
the other end of
the chest strap to
the sensor unit.
Adjust the length
of the chest
strap, if neces-
sary. The heart
rate monitor should be under your clothing, tight against
your skin, and as high under the pectoral muscles or
breasts as is comfortable. Make sure that the logo on
the sensor unit is facing forward and is right-side-up.  

Pull the sensor unit away from your body a few inches
and locate the two electrode areas on the inner side.
The electrode areas are the areas covered by shallow
ridges. Using saline solution such as saliva or contact
lens solution, wet both electrode areas. Return the
sensor unit to a position against your chest. 

HEART RATE MONITOR CARE AND MAINTENANCE   

• Thoroughly dry the heart rate monitor after each

use. The heart rate monitor is activated when the
electrode areas are wetted and the heart rate moni-
tor is put on; the heart rate monitor shuts off when it
is removed and the electrode areas are dried. If the
heart rate monitor is not dried after each use, it may

remain activated longer than necessary, draining the
battery prematurely.

•  Store the heart rate monitor in a warm, dry place. 

Do not store the heart rate monitor in a plastic bag
or other container that may trap moisture. 

•  Do not expose the heart rate monitor to direct 

sunlight for extended periods of time; do not expose
it to temperatures above 122° Fahrenheit (50°
Celsius) or below 14° Fahrenheit (-10° Celsius). 

•  Do not excessively bend or stretch the sensor unit

when using or storing the heart rate monitor.

•  Clean the sensor unit using a damp cloth—never

use alcohol, abrasives, or chemicals. The chest
strap may be hand washed and air dried.

HEART RATE MONITOR TROUBLE-SHOOTING

The instructions on the following pages explain
how the heart rate monitor is used with the console.
If the heart rate monitor does not function properly,
try the steps below.

• Make sure that the heart rate monitor is worn as de-

scribed at the left. Note: If the heart rate monitor
does not function when positioned as described, try
moving it slightly lower or higher on your chest.

• Use saline solution such as saliva or contact lens

solution to wet the two electrode areas on the
sensor unit. If heart rate readings do not appear until
you begin perspiring, re-wet the electrode areas.

• As you walk or run on the treadmill, position your-

self near the centre of the walking belt. For the 
console to display heart rate readings, the user
must be within arm’s length of the console.

• The heart rate monitor is designed to work with 

people who have normal heart rhythms. Heart rate 
reading problems may be caused by medical 
conditions such as premature ventricular contrac-
tions (pvcs), tachycardia bursts, and arrhythmia.

• The operation of the heart rate monitor can be 

affected by magnetic interference caused by high
power lines or other sources. If it is suspected that
this is a problem, try relocating the treadmill.

• The CR2032 battery may need to be replaced (see

page 27).

HOW TO USE THE HEART RATE MONITOR

Chest Strap

Tabs

Sensor Unit

Tab

Buckle

PROBLEM: The heart rate monitor does not function properly 

SOLUTION: a. If the heart rate monitor does not function properly, see HEART RATE MONITOR TROUBLE-

SHOOTING on page 6. 

b. If the heart rate monitor still does not function properly, the battery

should be changed. To replace the battery, locate the battery cover
on the back of the sensor unit. Insert a coin into the slot in the cover
and turn the cover counterclockwise to the “open” position. Remove
the cover.  

Remove the old battery from the sensor unit. Insert a new CR 2032
battery
, making sure that the writing is on top. In addition, make sure
that the rubber gasket is in place in the sensor unit. Replace the bat-
tery cover and turn it to the closed position.

Battery

Rubber

Gasket

Battery Cover

Battery

Cover

b

Summary of Contents for 10.6qi

Page 1: ...ness Ltd Unit 4 Revie Road Industrial Estate Revie Road Beeston Leeds LS118JG UK email csuk iconeurope com 08457 089 009 HOW TO ORDER REPLACEMENT PARTS To order replacement parts contact the ICON Heal...

Page 2: ...same circuit 12 If an extension cord is needed use only a 3 conductor 1mm2 14 gauge cord that is no longer than 1 5 meters 13 Keep the power cord and the surge suppres sor away from heated surfaces 1...

Page 3: ...hand weights should be attempted only by ex perienced users 19 Never leave the treadmill unattended whilst it is running Always remove the key unplug the power cord and move the on off switch to the...

Page 4: ...ach week if desired The key to success is to make exercise a regular and enjoyable part of your everyday life SUGGESTED STRETCHES The correct form for several basic stretches is shown at the right Mov...

Page 5: ...ou must exercise at a low intensity level for a sustained period of time During the first few minutes of exercise your body uses easily accessible carbohydrate calories for energy Only after the first...

Page 6: ...asives or chemicals The chest strap may be hand washed and air dried HEART RATE MONITOR TROUBLE SHOOTING The instructions on the following pages explain how the heart rate monitor is used with the con...

Page 7: ...y until the Magnet is aligned with the Reed Switch Make sure that the gap between the Magnet and the Reed Switch is about 3 mm 1 8 If necessary loosen the Reed Switch Screw 26 and move the Reed Switch...

Page 8: ...console is in the manual mode the speed and incline of the treadmill can be changed with a touch of a button As you exercise the console will display instant exercise feedback you can watch your progr...

Page 9: ...utton is used to start the walking belt P Mode indicators These indicators show whether the manual mode a performance program a total body workout program a pulse program a custom program or an iFIT c...

Page 10: ...determin ing heart rate trends in general If you have heart problems or if you are over 60 years of age and have been inactive do not use the pulse programs If you are taking medication regularly cons...

Page 11: ...n or the treadmill will be damaged Next remove the key from the console Keep the key in a secure place Note If the console remains lit after the key is removed refer to page 23 and turn off the demo m...

Page 12: ...y by experienced users HOW TO USE IFIT COM CD AND VIDEO PROGRAMS To use iFIT com CD s or videocassettes the treadmill must be connected to your portable CD player portable stereo home stereo computer...

Page 13: ...e will change during the pulse programs Note that the program display shows a simplified profile of the program Enter your age When a pulse program is selected the letters AGE will appear in the Pulse...

Page 14: ...ease the speed the incline will automatically decrease if you decrease the speed the incline will increase If you increase the incline the speed will decrease if you decrease the incline the speed wil...

Page 15: ...ble 3 5mm Splitter Headphones B HOW TO USE THE SELECT TARGET PULSE PROGRAM Insert the key fully into the console See HOW TO TURN ON THE POWER on page 10 Select the Select Target program When the key i...

Page 16: ...n teen periods will be shown in the seventeen columns to the right 4 3 2 1 7 6 If your heart rate is not detected during the pro gram the Pulse display will be blank See HEART RATE MONITOR TROUBLE SHO...

Page 17: ...24 3 114 43 41 43 43 40 39 40 40 43 120 121 61 117 43 119 129 118 43 43 43 123120 61 123 123 123 129 4 49 50 20 88 29 25 28 23 13 131 112 113 103 102 59 134 40 40 94 137 32 26 26 26 26 108 34 26 7 26...

Page 18: ...81 82 40 83 40 75 40 86 87 87 91 46 93 30 40 95 97 96 105 109 106 107 104 85 40 51 26 36 110 75 92 46 74 132 122 94 13 76 77 78 98 59 133 133 73 13 73 13 76 78 77 13 133 67 68 69 71 72 70 10 EXPLODED...

Reviews: