Page 66
Setup and Assembly Manual
D
Technical Data
D.1
Scanner Specifications
Optical System
Maximum document width
25 x 17.7 inches / 635 x 450 mm
Resolution
1200 dpi
Sensor type
Two tricolor CCDs, encapsulated and dust-
proof
12 bit grayscale (internal resolution)
36 bit color (internal resolution)
Sensor resolution
45,000 pixels (2x 22,500)
Scan modes
24 bit color, 8 bit indexed color
8 bit gray scale
1 bit Black/White
Scan accuracy
± 0,1%
Illumination
Light source
Two lamps with white LEDs
Warm-up time
None. Maximum brightness immediately after
switch-on.
Temperature dependence
None
UV / IR emission
None
Lifetime
50,000 hours scanning time
Glass plate
Mechanical load (maximum)
10 kg
Important
: Do not exceed the maximum load!
D.2
Ambient Conditions
Operating temperature
+5 to +40 °C / +40 to +105 °F
Storage temperature
0 to +60 °C / +32 to +140 °F
Relative humidity
20 to 80% (non-condensing)
Noise level
48 - 53 dB(A) (Operating)
33 dB(A) (Stand-by)