Setup and Assembly Manual
Page 65
Error codes, part 3
Error # Error message shown in
the display
Error message sent to
application
Problem description
70
Error 70:
ADC error camera 2
Camera 2 adc error.
Test data transfer through analog
digital converter failed. Check cables
/ connectors to camera 2.
75
General keyboard error
General keyboard error. Check
keyboard and cables.
80
E80 BAD LAMP CONFIG
Bad lamp config
81
E81 BAD DEVICE CONFIG Bad device configuration
99
Internal error.
The firmware has detected an
internal error of unknown cause.
C.8.2
Warnings
Warning
#
Warning shown in the
display
Warning sent to
application
Problem description
144
Light level is low
The light level is found to be low
during the white balance function.
145
Camera adjustment required Camera adjustment required
160
W160 NO WHITE
BALANCE DATA
No white balance data
No white balance data was found.
Perform white balance.
C.8.3
Information
Info. # Information shown in the
display
Information sent to
application
Description
200
CREATING
RECOVERY PART..
Creating Recovery Partition While creating the recovery partition,
the scanner can not be accessed.