Rangehoods and overhead exhaust fans must be installed according to the manufacturers’ instructions
and local regulations but in no case shall clearance from hob burners be less than 600mm for the
rangehood and 750mm for the overhead exhaust fan.
At all times gas safety regulations and local building codes must be adhered to.
Removing Legs and placing oven on a plinth If the legs are removed and the oven is placed on a plinth,
then suitable ventilation from the plinth area is required. It is recommended that an air vent 20 mm wide
and a length of 100mm less than the width of the oven it is be located at the rear in the base of the plinth.
If the area under the plinth is sealed it is also recommended that an additional vent be included at the top
of kick panel under the plinth to provide adequate circulation. The vent size should be 10mm high and
100mm less than the width of the oven.
clearances
freest
anding cookers
38
ILVE Freestanding Operating Manual