background image

Ilumiline 36 IP Optic RGB QRG 

 

Ilumicon 

and DMX 

Controllers 

 

The Ilumiline 36 IP Optic RGB can operate with either an Ilumicon or a 
DMX controller. Use the standard DMX connection, as shown on the 
previous section (

DMX Junction Box Wiring

) to connect this product to 

any of those controllers.  

For more information, please refer to the 

Ilumiline 36 IP Optic Series User 

Manual

 

 

 

Settings 

 

To configure the Ilumiline 36 IP Optic RGB, use the Ilumicode. 

 

 

 

Ilumicode 

Connections 

 

The diagram below shows how to connect the Ilumicode to this product.  

Note that this connection will control multiple fixtures at the same time, 
all having the same DMX address. To assign individual DMX addresses to 
each fixture, you must connect the Ilumicode unit to each fixture, 
individually. This means that you will also have to disconnect the DMX 
output of the fixture under configuration if there are other fixtures 
connected to it. 

 

 

 

Ilumicode 

Connection 

Diagram 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

ILUMINARC suggests you to connect no more than 20 fixtures in this 
mode, while keeping the total distance to less than 60 m (197 ft). 
Otherwise, you might need to use an optically isolated signal amplifier.

 

     

 

 

Ilumicode 
Addresser 

Summary of Contents for Ilumiline 36 IP Optic RGB

Page 1: ...Ilumiline 36 IP Optic RGB Quick Reference Guide ...

Page 2: ...duct when operating because it may be hot DO NOT leave any flammable material within 50 cm from the product while operating or connected to the power outlet to minimize the risk of fire DO NOT mount the product overhead without using a safety cable DO NOT submerge this product IP66 Regular outdoor operation is fine DO NOT operate the product if you see damage on the housing lenses or cables Have a...

Page 3: ...er RGB color macros strobe dimmer speed Dimmer speed control Static color control without DMX controller High power 1 W 350 mA LEDs 12 red 12 green and 12 blue Cast aluminum IP66 gray housing Impact resistant glass lens cover Adjustable brackets Options Ilumicode controller for fixture configuration Ilumicon controller for operation without DMX controller Installed non changeable optical system 60...

Page 4: ... the Ilumiline 36 IP Optic RGB User Manual and follow the mounting procedures This product comes with two adjustable brackets to mount on any firm non flammable surface whether horizontally or vertically on the floor or hanging from a truss Mounting Diagram Power In Signal In Out Gore Valve Brackets Safety Loop ...

Page 5: ...n connect the bare ended IP66 rated power cable from the product to an IP66 rated power connector or use an IP66 rated junction box If using an IP66 rated junction box make sure to use IP66 rated conduit Power Cable Table Connection Wire US Wire Europe IP66 Pin AC Live Black Brown 1 AC Neutral White Blue 2 AC Ground Green Yellow Green Yellow 3 AC Power Junction Box Wiring ...

Page 6: ... this product you can connect the bare ended IP66 rated signal cable from the product to two IP66 rated signal connectors DMX in and DMX out or use an IP66 rated junction box In this case make sure to use IP66 rates conduit The signal cable must match or exceed the electrical characteristics of the Belden 9841 cable for EIA RS 485 applications You can also use CAT 5 CAT 5e or CAT 6 DMX Junction Bo...

Page 7: ...m below shows how to connect the Ilumicode to this product Note that this connection will control multiple fixtures at the same time all having the same DMX address To assign individual DMX addresses to each fixture you must connect the Ilumicode unit to each fixture individually This means that you will also have to disconnect the DMX output of the fixture under configuration if there are other f...

Page 8: ...r sets the currently selected value into the selected function UP Navigates upwards through the menu options and increases the numeric value when in a function DOWN Navigates downwards through the menu options and decreases the numeric value when in a function Start Address To ensure full access to all channels in each DMX mode the highest recommended DMX addresses are as follows Mode Address Mode...

Page 9: ...nel RGB per module CALIB WHITE 1 11 RED 0 255 GREEN 0 255 BLUE 0 255 Determines the white balance for the color macros RGB Determines the white balance when RGBTOW is active DIMMER OFF N A Dimmer work in linear mode DIM 1 Dimmer works in non linear mode from fast to slow DIM 2 DIM 3 DIM 4 STATIC RED 0 255 Configures the static color and effect GREN BLUE STRB SETTINGS COLOR OFF Maximum output unbal...

Page 10: ...240 241 ó 245 246 ó 250 251 ó 255 No function Red 100 Green Up Blue 0 Red Down Green 100 Blue 0 Red 0 Green 100 Blue Up Red 0 Green Down Blue 100 Red Up Green 0 Blue 100 Red 100 Green 0 Blue Down Red 100 Green Up Blue Up Red Down Green Down Blue 100 White 1 3 200 K White 2 3 400 K White 3 4 200 K White 4 4 900 K White 5 5 600 K White 6 5 900 K White 7 6 500 K White 8 7 200 K White 9 8 000 K 6 Stro...

Page 11: ...mmer 000 ó 255 0 100 2 Red 000 ó 255 0 100 3 Green 000 ó 255 0 100 4 Blue 000 ó 255 0 100 SOLID Channel Function Value Percent Setting 1 RGB Dimmer 000 ó 255 0 100 SPECIAL 1 Channel Function Value Percent Setting 1 Module 1 Red 000 ó 255 0 100 2 Module 1 Green 000 ó 255 0 100 3 Module 1 Blue 000 ó 255 0 100 4 Module 2 Red 000 ó 255 0 100 5 Module 2 Green 000 ó 255 0 100 6 Module 2 Blue 000 ó 255 0...

Page 12: ...ghting eu Chauvet France Address 3 Rue Ampère 91380 Chilly Mazarin France Voice 33 1 78 85 33 59 Email Eutech chauvetlighting com Website www chauvetlighting eu Chauvet Germany Address Bruno Bürgel Str 11 28759 Bremen Germany Voice 49 421 62 60 20 Email Eutech chauvetlighting com Website www chauvetlighting eu Chauvet Mexico Address Av de las Partidas 34 3B Entrance by Calle 2 Zona Industrial Lerm...

Reviews: