DMX
Connection
You can connect the bare-ended IP66 rated signal cable from the product to
two IP66 rated signal connectors (DMX in and DMX Out) or use an IP66
rated junction box. If using an IP66 rated junction box, make sure to use
IP66 rated conduit.
Signal Wiring
To provide a signal for this product, you can connect the bare-ended IP66
rated signal cable from the product to two IP66 rated signal connectors
(DMX in and DMX out) or use an IP66 rated junction box. In this case,
make sure to use IP66 rates conduit.
The signal cable must match or exceed the electrical characteristics of
the Belden 9841 cable for EIA RS-485 applications. You can also use
CAT 5, CAT 5e, or CAT 6.
DMX Junction Box
Wiring
DMX Cable Table
Connection
DMX In
DMX Out
IP66 Pin
Ground
Shield
Shield
1
Data -
Black
Green
2
Data +
White
Red
3