11
HANGING INSTRUCTIONS
Method 1
: Fixed mounting installation
Measure the holes for mounting and mount the product on a solid surface. Use a 6mm (15\64”)
drill bit to drill two holes on the wall; then put the screw expansion tube(M4) into installation holes.
Next, screw the two screws (M4*20) with a screwdriver. Screws need to be away from the wall about
16-18mm. Slide the controller down over the two screws. Use the orange X’s on this page as a
convenient drill template.
Method 2
: wall-mounted installation
Ensure all wires are secure. Install a nail / screw and then insert the mounting hook of the controller
over the nail / screw.
10
1-877-540-5588
iluminarlighting.com
© Copyright 2021, ILUMINAR Lighting
Subject to change without notice.
Use these sensor to monitor the temperature in a set environment. With a temperature shutoff, the
controller will automatically dim or shut down the lights if the climate room temperature becomes
too high.
- Keep the sensor out of direct light so the measured temperature is accurate.
- Insert the temperature sensor for group 1 into T1 or group 2 into T2.
- The temperature measured by the sensor will be displayed on the LCD.
- Place the temperature sensor as close as possible to the sensor of the existing climate control
system, so both sensors will measure the same temperature (A).
- Keep the sensor out of direct light in order to avoid disrupting the temperature measurement; if
necessary, please use a hood (B).
- Insert the plug of the temperature sensor into the T1 or T2 port (C).
Climate
Control
System
Temp sensor
shielded from
light
CONNECTING THE TEMPERATURE SENSOR