A. Setting: Group 1  and Group 2
B. Running Mode: Auto or Manual
                  Auto: Turn on or off (Auto on/Auto off)
                  Manual: Manual switch (ON/OFF)
C. Dimming %, range 50-115% for the ballast/ range 20-100% for the LED 
    track.
D. Set Manual switch (ON/OFF): Only select the manual mode that will be      
    in accordance with this setting
    Set Auto switch (Auto ON/OFF) , turn to Group1 Timing Time Set or 
    Group 2 Timing Time Set.

E. Sunrise/set:  ‘×’ Disable or ‘√’enable; Time setting 10~60min
F. Limited Temp: Temperature protection  ‘×’ Disable or ‘√’enable; 

   Protection temperature setting 70~120° F (21~49°)
G. Time Setting: Current time shown, touch to change time
H. Back: Cancel the parameter settings and turn back to the Monitoring 
    interface
I. Save: Save the set parameters and turn back to the Monitoring interface

Setting
If in setting mode and there is no screen use for 60 seconds 
the display will automatically return to monitoring mode.

Group1 Time setting

4

5

8

1-877-540-5588       

iluminarlighting.com                    

[email protected]

© Copyright 2021, ILUMINAR Lighting

Subject to change without notice.

9

If the actual temperature reaches one of the groups set temperature protection values, the 
temperature protection feature is enabled and will turn to the alarm interface. Press the BACK 
button to return to the monitoring interface, stay in the monitoring interface for 10 seconds, 
and then automatically switch to the alarm interface until the temperature alarm releases.

Group2 Time setting

6

Group2 Time setting

7

Group2 Time setting

8