Ilumen
7
Installation Manual Ilumen PID Box & Ilumen PID Control Box
4.2
I
LUMEN
PID
B
OX
The Ilumen PID Box is placed between the inverter and the solar array strings. The power of the
strings goes through the PID Box, entering on one side and leaving on the other.One Ilumen PID
Box can only be used for one MPP tracker. If you use multiple Ilumen PID Boxes you must couple
them together in series with the 4-pole connectors. Always terminate the last Ilumen PID Box 4-
pole connector in a non-conductive and weather resistant manner. The number of working
Ilumen PID Boxes can optionally be monitored through the Ilumen portal.
Attention:
If you work with inverters with multiple MPPT’s you cannot mix the PV arrays from
multiple MPPT’s.
Attention:
The maximum current that can pass through the Ilumen PID Box is 34A. Make sure this is
never exceeded.
Attention:
Make sure the PV arrays are connected to the “in” side of the Ilumen PID Box Mini, NEVER
to the “out”side.
5
M
OUNTING
5.1
M
OUNTING LOCATION REQUIREMENTS FOR THE
I
LUMEN
PID
C
ONTROL
B
OX
The installation site must be freely and safely accessible at all times without the
necessity for any auxiliary equipment.
The mounting location should be inside a rain- and windproof location.
Do not place in a dusty environment.
The mounting location should be maximum 50 meters from the first Ilumen PID Box.
The ambient temperature must be between -25 and 60°C.
The mounting surface must be even. The wall brackets of the Ilumen PID Control Box
must lie flush with the mounting surface.
5.2
M
OUNTING LOCATION REQUIREMENT FOR THE
I
LUMEN
PID
B
OX
It can be installed outside
Proper ventilation of the product is necessary.
The ambient temperature must be between -25 and 60°C.
The possibility to mount with screws has been foreseen but isn’t necessary