Installation Manual Ilumen PID Box & Ilumen PID Control Box
Knowledge of all applicable standards and directives
Knowledge and observance of this document and all safety precautions
2.3
S
AFETY PRECAUTIONS
2.3.1
E
LECTRIC SHOCK
When the Ilumen PID Solution is in operation, voltage will be present. Prior to maintenance
work on the PV plant switch off the Ilumen PID Control Box.
When you want to change the arrangement of the Ilumen PID Solution or want to add new PID
boxes you must switch off the Ilumen PID Control box 20 minutes prior to making any changes.
2.3.2
E
LECTROSTATIC DISCHARGE
Never operate the Ilumen PID Solution when not properly installed or when the components are
not closed properly. Always make sure the grounding of the Ilumen PID Control Box is done
correctly.
3
S
COPE OF DELIVERY
3.1.1
I
LUMEN
PID
B
OX
1.
1
x
Ilumen PID Box
2.
1
x
Cable with 4-pole male plug (M12)
3.
1
x
Cable with 4-pole female plug (M12)
4.
2
x
MC4 or SUNCLIX male connector
5.
2
x
MC4 or SUNCLIX female connector
3.1.2
I
LUMEN
PID
C
ONTROL
B
OX
1.
1
x
Ilumen PID Control Box
2.
1
x
Power cord (EU plug)
3.
1
x
Cable with 4-pole female plug (M12)
4.
1
x
Antenna
4
P
RODUCT DESCRIPTION
4.1
I
LUMEN
PID
C
ONTROL
B
OX
The Ilumen PID Control Box is connected with all the Ilumen PID Boxes in series When the
Ilumen PID Control Box is actively curing, the Ilumen sign is lit up. The curative periods of the
solution will depend on the extend of the PID problem. When no PID is present in the installation
the Ilumen PID Control Box will retain from curing. . Through GPRS communication the Ilumen
PID Solutionis switched on or off automatically. Through the my.ilumen.be portal you can check
if the Ilumen PID Control Box is operating correctly.You must mail the installations geographic
location to
together with the Ilumen PID Control Box serial number to get your
login details and activation.
The Ilumen PID Control Box may never be moved to another
geographic location before approval of Ilumen.