Ilumen
11
Installation Manual Ilumen PID Box & Ilumen PID Control Box
Unused DC inputs and outputs on the Ilumen PID Box are terminated with a
corresponding sealing plug
The Ilumen PID Boxes are correctly connected to the Ilumen PID Control Box
The final Ilumen PID Box is sealed in a non-conductive and weather resistant manner
If all these conditions are met you can start up the Ilumen PID Solution.
7.2
S
TARTING UP THE
I
LUMEN
PID
S
OLUTION
The Ilumen PID Control Box can only apply the Ilumen PID Solution in an automatic mode. It
must be connected to the my.ilumen.be portal via the GPRS at any time. To start up the Ilumen
PID Box, plug in the AC power cord into a standard EU outlet (This outlet must be on at all times)
and turn on the switch. Next you need to login to the my.ilumen.be portal to see if the connection
is good and to finalize the installation. After approving the system it will be switched on
automatically.
Mail geographic location to
together with the Ilumen PID Control Box serial
number to get your login details and activation.
The Ilumen PID Control Box may never be
moved to another geographic location before approval of Ilumen.
8
I
NSTALLATION SUMMARY
1)
Take the necessary safety precautions (AC side of the PV plant off and DC switch of the
inverter off).
2)
Mount the Ilumen PID Control Box.
3)
Make the AC power connection to the Ilumen PID Control Box with the power button
turned off.
4)
Connect the Ilumen PID Control Box and the PV frames to earth and make sure all PV
frames are interconnected.
5)
The Ilumen PID Box can be mounted.
6)
Disconnect the PV array cables from the inverter.
7)
Connect the PV array cables to the Ilumen PID Box (see
8)
Connect the Ilumen PID Box to the inverter (see
9)
Connect the Ilumen PID Box(es) in a series chain to the Ilumen PID Control Box.
10)
Flip on the power switch of the Ilumen PID Control Box.