background image

INSTRUCTIONS 

ILLY COLD BREW BROOD

 

 Weekly Cleaning  with  Cleaning  Bottle

 

Item  US04-1140 

Item  US3560 

2 STEP DILUTION PROCESS 

CLEANING; 

       URNEX CLEARLY COLD  

 

SANITIZING: 

       URNEX COMPLETE CAFE 

Container Size    Cleaner/Sanitizer          Water 

    1 Liter                        2.5 ML                    1 Liter 

Fill the cleaning  bottle  with 

500ml(½ liter) clean water  

Add 2.5ml Clearly Cold® solu-

tion to the bottle and fill with an 

additional 500ml (½ liter) of 

water and secure the lid

.  

Measure carefully

 

 

Turn off the pump switch on the  

front of the unit. 

 

Place a container  under the tap 

spout. Pull the tap handle 

down and purge any residual 

pressure from the system

.  

Disconnect  the black dispense 

line from  the Bag in Box.  

Attach the black ball connector on 

the dispense line to the stem on the 

cleaning bottle. Once attached, pull 

up to ensure it is secured, close  

the door of the unit ( with the bottle 

outside of the door)  and turn on 

Place a container under the tap spout. 

Run the solution through the system 
for 20 seconds and 

let stand for

 

15 minutes. 

Then run the remaining  

solution through the system.  
Turn off pump and disconnect the  
bottle.  

Rinse the cleaning bottle with  

clean warm water  

Repeat Steps 1–3 and 6–8 

using 

the Complete Cafe® sanitizing solution. 

Let stand only 

1 minute, 

then purge the 

system, turn off the pump and let the 

system 

air dry for 10 minutes. 

 

Fill the bottle with fresh water, turn 

on the pump and run 

1 liter 

of fresh 

water through the system before 

reattaching the Bag in Box (BIB.) 

and turning on the pump. 

BEFORE SERVING: 

Place a glass 

under the tap. Purge  air from the 

system, open the tap (pull down on 

tap handle) When the coffee flows 

freely, close the tap.  

The temperature should be 38-40°F in the unit.

  

10 

Summary of Contents for COLD BREW ARIA

Page 1: ...0 F 3 Inspect the dispense lines for black buildup or spots A If you detect black residue DO NOT USE THE UNIT The lines must be replaced Call illy Caffe Technical service to schedule a service call B...

Page 2: ...ld Cleaner See Chart 2 Place the basket insert into the solution or Toddy Nylon filter 3 Run 1 liter of water through the tap and Let sit for 15 minutes 4 After 15 minutes empty the remaining solution...

Page 3: ...e dispense line to the OUT stem of the keg and place the keg back into the unit 6 Place a container under the tap on the door To purge air from the system open the tap and turn ON the pump When the co...

Page 4: ...box 7 Place the bag in box stand inside unit with the taller open side on the right Turn bag in box upside down with the black ball lock connector on the dispense line in the downward position towards...

Page 5: ...e into the cardboard opening On the top of the box always record the date connected and expiration date Maximum 5 days after opening Connect the dispense line black ball connector to nozzle on the box...

Page 6: ...iner and let it soak for 15 minutes 5 6 CLEANING Urnex Clearly Cold Solution SANITIZING Urnex Complete Caf Solution Item US3560 Remove and rinse the keg and the grey air intake valve Re ll keg with 2...

Page 7: ...elease any residual pressure from the unit 4 Disconnect the black dispense line out from the keg or the BIB Bag in Box 5 Attach the black connector to the stem on the cleaning bottle and ensure it is...

Page 8: ...le Once attached pull up to ensure it is secured close the door of the unit with the bottle outside of the door and turn on Place a container under the tap spout Run the solution through the system fo...

Page 9: ...2 Check if there is coffee in the container Re ll if necessary 3 Check for proper connection of intake black ball lock on the dispense line to the OUT stem of the keg When nished turn the pump OFF and...

Reviews: