background image

COFFEE BAR MANUAL

  66

Item US04-1140

ILLY COLD BREW ARIA / KEGERATOR 

Weekly Cleaning with Cleaning Bottle

ITEMS NEEDED

Cold Brew Cleaning Bottle

Fill the cleaning bottle with liter 
of clean water and secure the lid.

2

Open the door of the unit and 
turn off the pump.

Place a container under the 
spout and open the tap to 
release any residual pressure 
from the unit.

4

Disconnect the black dispense 
line (out) from the keg or the 
BIB (Bag in Box).

5

Attach the black connector to 

the stem on the cleaning bottle 
and ensure it is tight. 

6

7

Turn the pump switch back on.

Place a container under the tap 
spout and run the entire liter of 
water through the system.

Re-attach the black dispense 
line connector to the keg or BIB 
(Bag in Box).

3

1

DAILY CLEANING

Immerse the tap spout in warm 
water for 5 minutes. 

Wipe down unit of any splash 
back or spills.

8

Summary of Contents for COLD BREW ARIA

Page 1: ...0 F 3 Inspect the dispense lines for black buildup or spots A If you detect black residue DO NOT USE THE UNIT The lines must be replaced Call illy Caffe Technical service to schedule a service call B...

Page 2: ...ld Cleaner See Chart 2 Place the basket insert into the solution or Toddy Nylon filter 3 Run 1 liter of water through the tap and Let sit for 15 minutes 4 After 15 minutes empty the remaining solution...

Page 3: ...e dispense line to the OUT stem of the keg and place the keg back into the unit 6 Place a container under the tap on the door To purge air from the system open the tap and turn ON the pump When the co...

Page 4: ...box 7 Place the bag in box stand inside unit with the taller open side on the right Turn bag in box upside down with the black ball lock connector on the dispense line in the downward position towards...

Page 5: ...e into the cardboard opening On the top of the box always record the date connected and expiration date Maximum 5 days after opening Connect the dispense line black ball connector to nozzle on the box...

Page 6: ...iner and let it soak for 15 minutes 5 6 CLEANING Urnex Clearly Cold Solution SANITIZING Urnex Complete Caf Solution Item US3560 Remove and rinse the keg and the grey air intake valve Re ll keg with 2...

Page 7: ...elease any residual pressure from the unit 4 Disconnect the black dispense line out from the keg or the BIB Bag in Box 5 Attach the black connector to the stem on the cleaning bottle and ensure it is...

Page 8: ...le Once attached pull up to ensure it is secured close the door of the unit with the bottle outside of the door and turn on Place a container under the tap spout Run the solution through the system fo...

Page 9: ...2 Check if there is coffee in the container Re ll if necessary 3 Check for proper connection of intake black ball lock on the dispense line to the OUT stem of the keg When nished turn the pump OFF and...