REVEXmax - User’s Manual
4
Measurements
connect the remaining current-carrying conductors by means of the test
lead + test tip to the instrument’s
R
ISO
/
I
ALT
terminal.
•
If a Welding equipment output - Protective earth is measured, connect the
appliance for testing:
–
For a one-phase or three-phase appliance with movable power supply
cord – connect the PE pin of its plug to the instrument’s
PE
terminal
by means of the optional test lead + crocodile clip. Then connect the
welding equipment output to the instrument’s
R
ISO
/
I
ALT
terminal by
means of the optional test lead + crocodile clip.
–
For a hard-wired appliance –
first disconnect the appliance from
the mains!
Connect the point of the PE connection to the instrument’s
PE
terminal by means of the optional test lead + crocodile clip. Then
connect the welding equipment output to the instrument’s
R
ISO
/
I
ALT
terminal by means of the optional test lead + crocodile clip.
•
If a Mains - Welding equipment output is measured, connect the appliance for
testing:
–
For a one-phase or three-phase appliance with movable power supply
cord – connect the current-carrying conductors by means of the test lead
+ test tip to the instrument’s
R
ISO
/
I
ALT
terminal. Then connect the
welding equipment output to the instrument’s
PE
terminal by means of
the optional test lead + crocodile clip.
–
For a hard-wired appliance –
first disconnect the appliance from the
mains!
Connect the current-carrying conductors by means of the test
lead + test tip to the instrument’s
R
ISO
/
I
ALT
terminal. Then connect
the welding equipment output to the instrument’s
PE
terminal by means
of the optional test lead + crocodile clip.
•
Switch on the tested appliance’s mains switch.
•
Press the
[TEST]
key. It is recommended that you hold the
[TEST]
key
down for 5-10 seconds (or even longer if the displayed result is not stabilized);
the influence of the tested appliance’s internal capacitance can be eliminated
by this method.
•
After finishing the measurement the last measured value is displayed.