PK3561_10_09 • 79 SERIES INSTALLATION GUIDE
14
number of times lock electronic overrides can be performed
with the M-Unit before resynchronization
Select unit(s) from list that appears when you click on the tree
at right
Click on Save
The folder to hold your files to transfer to the locks, is called
ATLAS M-Unit and is located in the Main folder for your ATLAS
application
Leave the default name that shows the date the file was cre-
ated. The extension is .lcf for “lock configuration file”
Click Save
STEP 2 – Create Initialization and Programming key-
cards
An
Initialization keycard
initializes the lock during a first-time
installation, or after an interruption of battery power (e.g. dur-
ing a battery replacement, or whenever the battery power is
temporarily disconnected).
Log in to ATLAS-Multi-Housing and select
Make keycards
from the main
Staff
menu
Select
Initialization
from the drop down menu
Enter the number of cards required
Placed the keycards on the encoder
Clear label the
Initialization keycards
A
Programming keycard
prepares the lock for communica-
tion with the M-Unit. If the lock has never been initialized, the
Initialization keycard must be presented to the lock prior to the
Programming keycard. If communication with the lock does
not begin within 30 seconds, the lock will return to the normal
state with no changes to its programming.
Log in to ATLAS-Multi-Housing and select
Make keycards
from the main
Staff
menu
Select
Programming
from the drop down menu
Enter the number of cards required
Placed the keycards on the encoder
Clear label the
Programming keycards
STEP 3 - Synchronize ATLAS-Multi-Housing with the
M-Unit
Turn on M-Unit
Ensure that your M-Unit is connected directly to the USB port
Click on the HotSync icon and you will receive a message that
the HotSync is in progress
Return to the main screen by clicking on the
Applications
icon
STEP 4 - Program Infrared Programming Module
(IPM)
Go to the main page of the ATLAS application on the M-Unit
Login with the same name and password you use for the main
application
Click on
ATLAS
at top left, and it changes to
Tools
, with a
dropdown menu
Select
IPM
from the pulldown menu under
Tools
Click on
IPM Configuration
. A list of available IPMs appears
Select the IPM you want to use
Click on
Program
and hold the M-Unit up to the IPM you are
programming. The M-Unit must be at least 2” away from the
IPM and the panel on top of the M-Unit must be parallel to the
IrDA window (small red glass panel) in the IPM, with the M-Unit
screen facing upwards.
STEP 5 - Program Lock
Click on
ATLAS
on the M-Unit screen
Tap on
Doors
. The list appears with all the lock numbers that
need to be programmed