PK3561_10_09 • 79 SERIES INSTALLATION GUIDE
13
B. Privacy Function: Lockout of Keycards
Turn the thumbturn to the horizontal position for privacy. (On
autodeadbolt models press and hold the auxiliary latch (X) to
extend the deadbolt, then turn the thumbturn for privacy. On
storeroom locks, skip this test.)
Present the Grand Master Keycard to the reader. The red LED
flashes once. Then turn the outside lever downward. The latch
does not retract.
C. Emergency Keycard Access:
Deadbolt Override
Present the Emergency keycard to the reader. The red LED
flashes for 4 seconds. Turn the outside lever downward while
the red LED is flashing. The deadbolt and latch bolt retract
simultaneously and fully.
While standing outside the room close the door and ensure that
it is properly latched. Open the door using the Grand Master
keycard using the same procedure.
D. Inside and Outside Lever Detection for
79T Toggle Mode only.
Before fastening the inside trim assembly to the outside
housing assembly, check that the lever switch (W2) is well
connected to the wire harness (W1) (see p.5). Check that the
thumbturn (T) is in the vertical position as shown in step 5
page 10.
Present the emergency card to the reader. (The LED will flash
for 4 seconds). Rotate the lever as soon as the LED starts
flashing - The LED will stop flashing. If it does not, there is a
problem with the lever detection
Deadbolt Deactivation:
A. Deadbolt Deactivation by Thumbturn
While standing inside the room, close the door, and then turn
the thumbturn to extend the deadbolt. (If the lock has an auto-
deadbolt mortise go to step B below).
Turn the thumbturn to retract the deadbolt. Repeat.
B. Deadbolt Deactivation by Lever
While standing inside the room, close the door and turn the
thumbturn to the horizontal position to extend the deadbolt
(or to select privacy on autodeadbolt models). Open the door
by turning the lever. The deadbolt and the latch bolt retract
simultaneously and fully. Take note of any excess friction
which might necessitate filing the strike (deadbolt area only).
Repeat.
Once a lock is correctly installed on the door and the battery
pack inserted, it will go into locked mode (always locked). In
this unprogrammed state (virgin mode), a lock can be unlocked
using one of the
Test Keycards
provided in a pack with the
installation equipment. While in virgin mode, the lock has no
address or date/time and will relock automatically after 4 sec-
onds once unlocked using a Test Keycard.
Locks need to be programmed to give them their door ID, to
synchronize them with the system date and time and program
them with all of the property setup settings (employees, sub-
master levels, etc.)
Once ATLAS-Multi-housing is installed on the dedicated laptop
or PC and the property’s System Setup has been configured by
the customer, locks are programmed using a Maintenance Unit
(M-Unit) and an Infrared Programming Module (IPM).
STEP 1 - Create Lock Configuration File
Log in to ATLAS-Multi-Housing and select
Transfer Files
M-Unit
> PC from the main
Admin
menu
Select Expiry for the length of time you want the files to remain
in the M-Unit. 24 hours is the default
If you select “Yes” to Electrical Override, another field “Number
of Overrides” appears, enabling you to limit the maximum
5 • Lock Programming