4000 Series Programmable Pushbutton Lock
17
Lock Operating Instructions
11. Set the factory-programmed lock configuration to Handicapped using
the Master authorization code 87654321.
#-8-7-6-5-4-3-2-1-#-8-0-2-#-#
12. Enable the passage mode using the Group 1 Manager authorization
code 1123456.
#-1-1-2-3-4-5-6-#-4-0-1-#-#
13. Chain a series of command codes using the Master authorization code
87654321. Disable the passage mode and return the lock to normal
lock mode, set the unlock time to eight seconds, set the lock tamper
shut-down time to fifteen minutes, and set the buzzer sound level to
soft.
#-8-7-6-5-4-3-2-1-#-4-0-0-#-5-0-8-#-6-1-5-#-7-0-1-#-#
14. Change the Master authorization code back to the factory default
12345678 using the Master authorization code 87654321.
#-8-7-6-5-4-3-2-1-#2-9-9-#-1-2-3-4-5-6-7-8-#-1-2-3-4-5-6-7-8-#-#
15. Set the lock configuration to Commercial (factory default) using the
Master authorization code 12345678.
#-1-2-3-4-5-6-7-8-#-8-0-0-#-#
16. Chain a series of command codes using the Master authorization code
87654321. Delete all users and then add the service access code 4000
(factory default).
#-8-7-6-5-4-3-2-1-#3-0-0-#-2-7-7-#-4-0-0-0-#-#
4000 Series Programmable Pushbutton Lock
16
4.3.3
Examples
The following examples can be performed on the lock in sequence.
1.
Set the tamper shutdown time to 30 seconds using the Master
authorization code 12345678.
#-1-2-3-4-5-6-7-8-#-6-0-0-#-#
2.
Change the factory-default Master authorization code from 12345678
to 87654321. Use the original Master authorization code 12345678 to
program the change and enter the new code twice to confirm it.
#-1-2-3-4-5-6-7-8-#-2-9-9-#-8-7-6-5-4-3-2-1-#-8-7-6-5-4-3-2-1-#-#
3.
Permanently delete all existing Manager authorization and User access
codes so that you can change the code length for maximum security
(from the default access code length of four—1234) using the Master
authorization code 87654321.
#-8-7-6-5-4-3-2-1-#-3-0-0-#-#
4.
Add the Group 1 Manager authorization code 1123456 using the
Master authorization code 87654321. Use the <*> key to correct the
mistakenly entered code 202 (adds a Group 2 Manager authorization
code).
#-8-7-6-5-4-3-2-1-#-2-0-2-*-2-0-1-#-1-1-2-3-4-5-6-#-#
5.
Add the Group 1 User 2 access code 12345 using the Master
authorization code 87654321.
#-8-7-6-5-4-3-2-1-#-2-1-2-#-1-2-3-4-5-#-#
6.
Add the Service access code 77777 using the Master authorization code
87654321.
#-8-7-6-5-4-3-2-1-#-2-7-7-#-7-7-7-7-7-#-#
7.
Temporarily disable (lockout) all Manager authorization codes, the
Service access code, and all User access codes using the Master
authorization code 87654321.
#-8-7-6-5-4-3-2-1-#-0-0-0-#-#
8.
Reactivate all temporarily disabled codes using the Master authorization
code 87654321.
#-8-7-6-5-4-3-2-1-#-1-0-0-#-#
9.
Change the Group 1 User 2 access code 12345 to 54321 using the
Group 1 Manager authorization code 1123456.
#-1-1-2-3-4-5-6-#-2-1-2-#-5-4-3-2-1-#-#
10. Permanently delete the Service access code 77777 using the Group 1
Manager authorization code 1123456.
#-1-1-2-3-4-5-6-#-3-7-7-#-#
Chapter 4