- AF35........................no
- DS50........................yes, above serial number 70000
- DS51........................yes
- DS125......................yes, above serial number 5000
- DS160, DS161 ........yes
- DS200......................yes, above serial number 7163
- Non-Ikelite ..............yes, manual flash exposure only
Strobe Compatibility
Ikelite Housing Conversion Circuitry
This small compact housing has Ikelite designed and patented
Conversion Circuitry built right in. The Conversion Circuitry provides real
TTL flash exposure when used with Ikelite DS series strobes. The
Circuitry is automatically activated once a DS series strobe is attached
to the housing and turned on. Once attached, turn the strobe on first
before turning on the camera. The circuitry cannot be powered up or
used by non-Ikelite strobes.
For MANUAL flash operation:
Depress the button 4 consecutive
times rapidly to switch from TTL to Manual flash mode. To return to TTL
mode, turn the strobe off and on again, and then return the strobe to
TTL operation.
Attach Ikelite Sync Cord to the Housing and Strobe
15
The Ikelite Housing and Strobe Bulkheads are designed to accept sync
cords with Ikelite 5 pin connector fittings.
1. Lightly lubricate the Sync Cord O-rings. Use ONLY Ikelite lubricant
(supplied with housing). Other lubricants may cause the o-rings to swell
and seal improperly.
2. Remove Bulkhead Caps from Housing Bulkhead and Strobe Bulkhead.
STROBE COMPATIBILITY and CONNECTION
Reference Diagram E, Page 16