5.
Advanced Usage Methods
5.1. External Synchronization
If this equipment is used with external synchronization, SYNC is input to the GENLOCK
connector on the back of the CCU. If SYNC is input to the GENLOCK connector, the camera
automatically switches from internal synchronization to external synchronization.
SYNC input conditions: Tri-Level SYNC: 0.6 Vp-p / 75 ohms
5.1.1 Wiring connection example
Prepare two sets of CCU and camera for MKC-230HD.
Connect the SYNC connector of
CCU
(Master) and the GENLOCK connector of CCU (Slave) with the coaxial cable.
CCU (master)
CCU (slave)
Camera (master)
Camera (slave)
Coaxial cable
(Sold separately)
SYNC connector
GENLOCK connector