E-14
VARIABLE SHUTTER
SPEED L・・・・I・・・H
1/60
RET EXIT
LIGHT CONTROL
BACKLIGHT CMP. OFF
BLC LEVEL L・・・・I・・・H
WIDE BLC OFF
IRIS LEVEL L・・・・I・・・H
RET EXIT SPOT SET
5-4-3. SHUTTER
(1) This mode is effective, when the light control is LENS mode.
(2) By L or R button, high speed shutter can be valid for OFF, FL, 1/125, 1/250, 1/500,
1/1000, 1/2000, 1/4000, 1/10,000, or Variable.
(3) VARIABLE
Speed of shutter can be changed
variably by L or R button. and the shutter
speed can be displayed on a monitor
screen. (When the setting was so made)
5-4-4 LIGHT CONTROL
(1) Select LIGHT CONTROL on the main menu using L or R button for AES or
LENS set. The Iris level can be displayed only when a lens changeover switch
was on DC mode.
(2) BACKLIGHT CMP.
W i t h t h i s m o d e , t h e b a c k l i g h t
compensation modes can be controlled
by L or R button. (for ON, SPOT, or OFF).
①
OFF
The backlight compensation is not
active. This is the factory setting.
②
SPOT
In this mode, the Spot measurement
can be made by setting the desired point.
③
ON
This mode is an ordinary back light compensation.
(3) BLC LEVEL
Move the marker by L or R button. Factory setting is at the middle.
The good result can be seen by moving marker to the right side, when the
difference of light amount was larger. It is recommended to control this by
watching the monitor screen.