⑯
Terminal switch for RS-485
In RS-485 communication link , turn this switch to ON side for one-to-one control,
or turn it to OFF side for daisy-chain(loop connection).
(For use in daisy-chain connection, turn ON the terminal switch of the last device
in the link.)
⑰
RS-485 connection terminal block
To be used for RS-485 connection.
⑱
DC12V/AC24V power input terminal
For power, apply the input power of DC10.5 - 28.0 V or AC24V
±
10%.
* This installation should be made by a qualified service person and should
conform to all local codes.
⑲
AC 100V power cable (In NTSC, Japanese version Only)
For AC 100V power supply.
Applicable AC should be within a range of plus/minus 10% voltage.
Note:
This camera has no power switch.
Just plug in the power cable and the camera power turns ON. To make the
camera power off, just unplug a power cable.
The power outlet should be handy near the camera and should be easily
accessible.