background image

Operating Instruction

Before filling the air cooler, make sure the unit is unplugged.

INSTRUCTIONS FOR USING AIR COOLER PLUS WITH WATER

1.

Make sure plug on bottom of unit is secure.

2.  Open the water inlet by pressing the panel on the lower left side of unit.

3.  Fill the water reservoir with cold, clean water; add small Ice Pods if desired.

4.  Fill reservoir only to water line indicator to avoid overfilling.

5.  After filling, close the water inlet securely. Use care when transporting filled 

air cooler. 

6.  Place the water filled air cooler on a FIRM, FLAT AND LEVEL surface

(To safeguard fine wood finishes, put a protective covering between air 

cooler and surface).

7.  Plug air cooler into wall outlet and switch on the unit. You must also press 

the cool button to activate cooling (Do not plug in the air cooler with wet 
hands, an electric shock could occur).

8.  The water will last 20 to 22 hours (Check water level periodically).

9.

The small plastic Ice Pods for cooling with water can be placed in the 
freezer for one to two hours until frozen hard, then added to the water 
reservoir. The colder the water, the cooler the air.

INSTRUCTIONS FOR USING AIR COOLER PLUS WATERLESS COOLING

1.  Place the Gel Packs for waterless cooling in the freezer for at least 2 hours. 

2.  Place frozen Gel Packs in Gel Pack Container, slide into cooling chamber  

and PRESS ON.

Storage

1. Clean and dry the cooler thoroughly per cleaning instructions before storing.

2. Be sure all components are dry. Do not leave any water in the air cooler 

when storing. Water left in the air cooler may cause deposits or bacterial 
growth which could impair the air cooler's performance.

6.

8)  Gel Packs: Cooled Gel Packs are placed in Gel Pack Container and then  

slid into the Cooling Chamber  - used in waterless cooling.

9)  Plastic Ice Pods: Use these in water reservoir to keep water cold.

10)  Handle of Gel Pack Container placed in Cooling Chamber.

11)  Gel packs in Cooling Chamber.

12)  Water Reservoir: Water for the cooling function is stored here. 

(maximum capacity is 6.5 liters or approximately 1.5 gallons).

13)  Rubber Plug and Water Outlet: Remove this plug when draining the    

water from the water reservoir. 

14)  Casters: These wheels make it easy to move from room to room.

15)  Water Inlet: The entrance for filling the water reservoir.

16)  Copper Casing helps keep Gel Packs cold.

17)  Handle: To use in transporting the unit.

18)  HEPA Filter: Replaceable filter removes 99.97% of particles in air.

3.

10

8

17

14

15

13

12

16

(2) Gel Packs

(2) Plastic Ice  

Pods

11

18

9

Summary of Contents for A4024

Page 1: ...Air Cooler PLUS user manual ...

Page 2: ...iginal place of purchase or visit www rppurchase com Thank You for purchasing the exclusive Air Cooler PLUS air cooler air filter humidifier and fan all in one attractive easy care unit The Air Cooler PLUS is a multi function unit It can be used as a fan an air cooler without water an air cooler with water an air filter and a humidifier Read this entire manual before using any of the functions Gua...

Page 3: ...l lower the temperature without increasing humidity 3 To use the air cooler with water and air filter Add water to the water inlet see diagram on pg 3 Use very cold water There are two 2 small plastic Ice Pods that can be placed in your freezer for a few hours then added to the water in the water reservoir These Ice Pods will keep the water cold much longer The colder the water the cooler the air ...

Page 4: ...s the water level in the water reservoir so you know when to add more water 5 Power Cord Its length is 6 feet 6 Remote Control You can use your remote control to operate the unit from the comfort of your chair The remote is magnetic and can attach to the side of the cooler so you always know where to find it 7 Control Panel The indicators of the timer swing cool power and speed switch 2 Nev coo Pe...

Page 5: ...ling function is stored here maximum capacity is 6 5 liters or approximately 1 5 gallons 13 Rubber Plug and Water Outlet Remove this plug when draining the water from the water reservoir 14 Casters These wheels make it easy to move from room to room 15 Water Inlet The entrance for filling the water reservoir 16 Copper Casing helps keep Gel Packs cold 17 Handle To use in transporting the unit 18 HE...

Page 6: ...er d Do not let children play with the air cooler Safety precautions while using air cooler a This product is equipped with polarized alternate current 3 prong plug Use only outlets that accept this plug do not use an adapter b Always unplug and empty air cooler before servicing or cleaning Never turn on the power while it is unplugged from a power source c Never tilt or attempt to move air cooler...

Page 7: ...er reservoir Water must be in the water reservoir for this function to work Do not use this when cooling without water and Gel Packs 5 ON OFF SWITCH Press this button to start the unit 6 REMOTE CONTROL You can use your remote control to operate the unit controlling all the above functions from your chair The remote is magnetic to attach to the side of the cooler so you always know where to find it...

Page 8: ... also press the cool button to activate cooling Do not plug in the air cooler with wet hands an electric shock could occur 8 The water will last 20 to 22 hours Check water level periodically 9 The small plastic Ice Pods for cooling with water can be placed in the freezer for one to two hours until frozen hard then added to the water reservoir The colder the water the cooler the air INSTRUCTIONS FO...

Page 9: ...l water tank with water and 1 cup of undiluted white vinegar Clean tank with a soft brush or cloth 4 To clean the outside of the air cooler use mild detergent 5 Depending on air quality and use of cooler the HEPA air filter may need to be changed after 6 to 12 months The filter is located between the cooling chamber and back of unit It slides out easily Extra filters may be ordered by contacting y...

Page 10: ...n order to avoid a hazard Do not immerse whole unit in water It might cause the breakdown or electrical shock if the PC board or other electrical components get wet The usage of a chemical solution such as a volatile oil or bleaching may result in damage to the ABS casing If the unit is not completely dried before storage the humidity enclosure of the unit provides a living environment for bacteri...

Page 11: ...IMPLIED WARRANTIES ARE LIMITED TO THE TERMS OF THE EXPRESS WARRANT GRANTED HEREIN Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you For 1 year from the date of original purchase the warrantor shall provide the repair or replacement of the product without charge to the consumer Unit not intended for commercial use Warranty Restr...