background image

17

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

4. Install a light layer of glowing embers (rockwool) directly over the ports.

    - A light layer will give a more constant rear flame.

    - A heavy layer will give more glow, but will need to

      be adjusted after light up.

5. Install front logs on retainer slots.

Face Installation

The faces come with hooked brackets. To install the face, hang the hooked 

brackets on the surround brackets (See C in 

Figure 13

)

.

1. Remove the speed nuts (A in 

Figure 13

)

 from the parts bag and 

install (with the flat surface forward) on the six holes in the surround 

brackets - three on each side of the insert (B in in 

Figure 13

)

. A flat 

bladed screwdriver may help in installing the nuts.

2. Install all surround panels and trim with the appliance positioned in 

the fireplace, but a few inches in front of its final location.

3. If an Arch face is to be installed on the appliance, the sight obstructor 

that comes with the face must be installed prior to installing the sur-

round panels. See the instructions included with the face for proper 

sight obstructor installation.

4. Install the side surround panels by lining up the holes in the tabs on the 

side surround panels in front of the holes on the surround brackets. 

Next insert two slotted 1/4" truss screws for each side surround panel 

and secure loosely. 

5. Fasten the top surround panel with the remaining two truss screws. 

Tighten all six truss screws after adjusting the surround panels to  

eliminate space between side and top surround panels.

6. Assemble the surround trim by inserting the elbowed retainer in the 

rectangular slot in the ends of the longest piece of trim  and secure by 

tightening the screw in the retainer. Slide the mitred ends of the two 

side trim pieces onto the elbowed retainer and secure by tightening 

the retainer screw.

7. The fastened trim pieces should now be horseshoe shaped. Slide the 

trim down over the surround panels so the edge of the surround panel 

fits just behind the rounded edge of the trim.  

8. Install three spring clips (found in parts bag in firebox) in each piece of 

trim by inserting them between the rear of the surround and the channel 

of the trim. The spring clips will push the trim tight to the surround.

6. Place volcanic stones around the perimeter of the glowing embers 

(rockwool). 

 

IMPORTANT!!! Do not cover the ports with the embers.

7. Place top log on pin.

Surround Installation

The fireplace insert surround panels are made of heavy gage steel for 

durability and, if desired, for the ease of making an inside fit in the fire-

place. See 

Packaging List

 for available sizes.

Figure 10

Figure 11

A

Figure 13

B

C

Spring Handle Latches

Door Mounting Plates

Figure 12

Front Logs

Top Log

Ports

Summary of Contents for Ravenna RDV33

Page 1: ...tely Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage...

Page 2: ...ALIENTE CAUSARÁ QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NIÑOS DEBEN NUNCA TOCAR EL VIDRIO L écran pare étincelles fourni avec ce foyer réduit le risque de brûlure en cas de contact accidentel avec la vitre chaude et doit être installé pour la protection Des enfants et Des personnes à risques incluse avec le façade Requis Unabarrera diseñadaparareducirelriesgodequemadurasdesdelamir...

Page 3: ... en funcionamiento Supervise en forma cercana a los niños en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio Mantenga la ropa mobiliario gasolina y otros líquidos inflamables alejados de la chimenea Aún después de haber apagado el gas las superficies de la chimenea permanecen extremadamente calientes Asegúrese de colocar las Etiquetas de advertencia de s...

Page 4: ...kaging List 12 Ratings 12 Insert and Fireplace Dimensions 13 Clearances to Combustibles 14 Insert Leveling 14 Installation 15 17 Venting Installation 15 Zero Clearance Fireplace Installation 16 Firebox Liner Kit required accessory and Log Set Installation 16 Surround Panels Installation required accessory 17 Facade Installation required accessory 17 Gas Line Installation 18 Gas Pressure Requiremen...

Page 5: ...avec la surface chaude Il est recommandé d installer une barrière physique si des personnes à risques habitent la maison Pour empêcher l accès à un foyer ou à un poêle installez une barrière de sécurité cette mesure empêchera les tout petits les jeunes enfants et toute autre personne à risque d avoir accès à la pièce et aux surfaces chaudes 7 Tout écran ou protecteur retiré pour per mettre l entre...

Page 6: ...ndiéndola y apagándola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrola la chimenea Figura A o en el termostato de pared Figura B Seleccione el idioma que más se habla en la casa 2 Si se usa un control remoto para controlar la chimenea encuentre el transmisor y límpielo bien para quitar el polvo y aceite P...

Page 7: ...trôle le fonctionnement du foyer en le faisant basculerdeMarcheàArrêt etvice versa Nettoyez soigneusement la plaque murale de l interrupteur ou le thermostat mural pour éliminer la poussière et les traces de graisse ou d huile Collez l étiquette sur la surface de la plaque de l interrupteur mural qui contrôle le foyer Figure A ou du thermostat mural Figure B Choisissez la langue qui est principale...

Page 8: ...with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes Turn off gas and electrical power to the appliance and allow it to cool before cleaning or servicing the appliance If the barrier becomes damaged the barrier shall be replaced with the manufacturer s barrier for this appliance Si l écran est endommagé il doit être remplacé par celui fournit par le...

Page 9: ...er use solid fuels such as wood paper cardboard coal or any flammable liquids etc in this appliance Plated surfaces must be cleaned with glass cleaner and a clean soft cloth before firing the first time or fingerprints will remain permanently NEVER use brass polish to clean plated surfaces this will remove the plating CAUTION Hot while in operation Do not touch Severe Burns mayresult Keepchildren ...

Page 10: ...225 1 orStandard for Gas Equipped Recreational Vehicles and Mobile Housing CSA Z240 4 Must be vented directly to the outside in accordance with the latest edition of the National Fuel Gas Code and must never be attached to a chimney serving a separate solid fuel burning appliance Has been certified for use with either natural gas or propane Is NOT for use with solid fuels Is approved for sitting r...

Page 11: ... a nationally recognized testing and certification laboratory to ANSI American National Standard Institute gas appliance safety standards This appliance has been tested and certified to ANSI Z21 88 CSA 2 33 Standard for Vented Gas Fireplace Heater and CAN CGA 2 17 M91 and UL 307B Gas Burning Heating Appliances for Manufactured Mobile Homes in both USA and Canada This appliance has met all necessar...

Page 12: ...Contact your IHP dealer for details Packaging List To install your appliance an insert body face surround flange kit and firebox liner kit are required Insert Body Packaging List 1 Insert Body 1 Log Set 1 Bag of Embers 1 Fasteners 6 slotted 1 4 truss screws 6 speed nuts 9 spring clips 3 plastic adhesive wire restraints 1 Installation and Operation Manual Decorative Facade Kits One Required Contemp...

Page 13: ...ions Width of insert behind Surround Panels 31 1 4 794mm Rear height 19 3 4 502mm Insert depth into fireplace 16 406mm Flue collar diameter OD 2 15 16 75mm A B C D Figure 2 Figure 3 Minimum Fireplace Opening A 31 1 2 800mm Front Opening B 19 1 2 495mm Height C 18 457mm Rear Width D 16 406mm Fireplace Depth Top air duct will need to be removed for short ZC applications Replace tap tights when remov...

Page 14: ...Repeat these steps for each adjusting leg Facing and Mantel Clearances Please note that the RDV33 SDVI33 mantel clearances are 4 less than the RDV40 SDVI40 mantel clearances as shown in Figure 4A RDV40 SDVI40 and Figure 4B RDV33 SDVI33 CLEARANCES TO COMBUSTIBLES RDV40 SDVI40 Facing and Mantel Side View RDV33 SDVI33 Facing and Mantel Side View Hearth Protection Figure 4A Figure 5 Clearances Figure ...

Page 15: ...ctural damage or leakage if the fireplace is factory built The appliance may NOT be installed into the fireplace Figure 6b WARNING Direct VentFireplaceInsertVentRequirements Useliner listed to UL181 Factory made Air Ducts And Air Connec tors orUL1777 ChimneyLiners fortheAIRINTAKE Use liner listed to UL1777 ONLY for the EXHAUST Donotsubstitutetheheat ratedflexliner UL1777 forthe exhaustwithanyother...

Page 16: ...au fond de la chambre de combustion Cetorificedoitêtreobturéaumoyend isolantincombustible une fois la conduite de gaz en place The installer must mechanically attach the marking supplied with the gas fireplace insert to the inside of the firebox of the fireplace into which the gas fireplace insert is installed Conversion from Standard 40 000 BTU To Optional 33 000 BTU Input To convert input from 4...

Page 17: ...1 4 truss screws for each side surround panel and secure loosely 5 Fasten the top surround panel with the remaining two truss screws Tighten all six truss screws after adjusting the surround panels to eliminate space between side and top surround panels 6 Assemble the surround trim by inserting the elbowed retainer in the rectangular slot in the ends of the longest piece of trim and secure by tigh...

Page 18: ...ge to valve com ponents Verify that the tanks have step down regulators to reduce the pressure to safe levels LP and Natural Gas Supplies Your gas appliance is equipped from the factory for use with natural gas only as specified on the Safety Listing label attached to the appli ance This appliance can only be operated using propane gas LP if a certified fuel conversion kit provided by IHP is insta...

Page 19: ...LLUSTRATIONS ARE NOT TO SCALE Moving shutter bracket to the right will open shut ter to the left will close shutter Figure 15a Figure 15b SHUTTER ADJUSTMENT DETAIL See Detail Shutter Adjustment Shutter Adjustment Detail ...

Page 20: ...rea for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE INJURY OR LOSS OF LIFE WHAT TO DO IF YOU SMELL GAS DO NOT try to light the appliance DO NOT touch any electric switch do not use any phone in your building Immediately call you...

Page 21: ...pilot is lit turn gas control knob counterclockwise to ON Knob can only be turned to ON if the knob has popped out 11 To turn burner on turn ON OFF rocker switch to ON or set the thermostat to the desired temperature above room temperature 12 Adjust the flame height and heat output by turning the flame height knob clockwise for full flame and counterclock wise for reduced flame 13 Turn on the elec...

Page 22: ... gas valve and orifice may make a rushing or whistling noise If this noise is objectionable it can be reduced by turning down the flame Turning down the flame can reduce total heat output by more than 30 When the blower turns on the sound of rush ing air may be heard The blower sounds may be reduced by adjusting the speed control located on the blower assembly Also a slight clicking sound may be h...

Page 23: ...hes to the appliance for example a rocker switch and a wall thermostat Additional switches may affect the system resistance and increase the chance of the burner not igniting Follow the instructions included with the thermostat or remote control for wiring The thermostat remote control and rocker switch will turn the burner on and off independently Be sure to set the rocker switch to the OFF posi ...

Page 24: ...rubs and plantings that may encroach on the termination o Check gaskets once a year Gaskets must be tight Replace if neces sary o Inspect the pilot system for proper flame NEVER ADJUST THE PILOT untilafterthegaspressurehasbeencheckedandthesupplylineshave been completely bled this may take an hour or more when bleeding through the pilot All pilots are checked and burned at the factory prior to ship...

Page 25: ...mic and alternative types must not be used NOTE BE CAREFUL NOT TO SPRAY COMMERCIAL GLASS CLEANER WITH AMMONIA ON GASKET AREA OF DOOR AM MONIA WILL DISSOLVE GASKET GLUE Glass Door Only doors certified with the appliance shall be used Seules des portes certifiées pour cet appareil doivent être utilisées CAUTION DONOTabuseglassdoorbystrikingorslammingshut Do not remove glass door while the appliance ...

Page 26: ...Pcanbeaccomplished by installing a conversion kit valve regulator and burner orifice Only a qualified service technician should perform the conversion Conversion Kit Please see instructions provided with conver sion kit Blower Removal Unplug the power supply cord from the electrical outlet prior to removing theblower Theblowercanbeaccessedthroughthebackwallofthefirebox Remove the insert face glass...

Page 27: ...Part No J7510 2 Place sight obstructers back over the threaded studs taking note that the upper and lower horizontal bar ends line up with grooves in sight obstructers see Detail A in Figure 22 3 Reinstall the 3 8 nuts 4 Reinstall facade to the unit Cast Pillar Facade see Figure 23 1 Make sure the unit is off and cold 2 Remove the cast pillar facade door from the facade by gripping both sides firm...

Page 28: ...iter and igniter wire Using a match light pilot If pilot lights turn off pilot and trigger the igniter again If pilot lights an intermittent gas air supply may be the problem if longer purge will not light check gap between electrode and pilot should be 1 8 inch 3 mm to have a strong spark If OK replace pilot Pilot will not stay lit after carefully following lighting instructions Low gas inlet pre...

Page 29: ...Speed Control Wire for rheostat H5858 Log Set H5863 Bag of Embers volcanic stone H5864 Bag of Glowing Embers rockwool H3130 Firebox Door w Glass H5989 Hardware Package H5839 Log Set Support H5980 Knob Extension Kit Robertshaw Bay Face H8159 Touch Up Paint Metallic Black 12 oz aerosol J7510 Barrier on Contemporary facade J7511 Barrier on Pillar Cast facade REPLACEMENT PARTS RDV33 40 AND SDVI33 40 C...

Page 30: ...lack ref Form 775208M 75062 GFHKET G Extended Side Trim Gold ref Form 775208M 75063 GFHKET N Extended Side Trim Nickel ref Form 775208M ACCESSORIES RDV33 40 AND SDVI33 40 Tan Brick Red Brick Architectural Stone NOTE The form numbers referenced are the part numbers of the instruction sheets included in kits Product Reference Information Cat No Description Ship Weight Ship Volume H6967 RAV33 40DVI C...

Page 31: ...ickel 33 x 41 75043 GFT3348 N Trim Nickel 33 x 48 Pillar Cast Face Kits u NOTE 3 boxes to complete face 37 5 8 W x 23 3 4 H F2324 PILCST GLASS BARRIER Cast Door Box 1 of 3 ref form 775258M 75092 PILCST PILRS2 Back Pillars Top Box 2 of 3 75094 PILCST GRL TRD3 Grill bars Traditional Box 3 of 3 Or 75091 PILCST GRL FIL3 Grill filigree Ornate Box 3 of 3 45 1 2 1156mm 7 1 8 181mm 30 762mm 22 7 8 581mm u...

Page 32: ...ceiver may be wall mounted or placed in the valve compartment Cost Effective Solution Simple On Off operation Workswithmillivoltandlowvoltageelectronic ignition controls Kit includes Remote and Receiver Wall Thermostat Wall surface mounted Thermostat or manual ON OFF operation Large LCD screen to display room and set temperature in ºF and ºC Connects to wall switch wire Manual or up to 3 hr Countd...

Page 33: ...ERNIÈRE ÉDITION ETATS UNIS OU CAN CGA B149 1 DERNIÈRE ÉDITION CANADA CET APPAREIL DOIT ÊTRE INSTALLÉ SELON LES DIRECTIVES D INSTALLATION DU FABRICANT POUR INSTALLATION DANS DES FOYERS À COMBUSTIBLE SOLIDE SEULEMENT DE MAÇONNERIE OU PRÉFABRIQUÉ EN USINE CE FOYER RADIANT AU GAZ À ÉVACUATION N EST PAS CONÇU POUR ÊTRE UTILISÉ AVEC DES FILTRES À AIR CET APPAREIL DOIT ÊTRE UTILISÉ AVEC LE TYPE DE GAZ IN...

Page 34: ... allumage de la veilleuse B AVANT D ALLUMER L APPAREIL assurez vous qu il n y a pas d odeur de gaz près de l appareil ni près du sol car certains gaz plus lourds que l air auraient tendance à s y accumuler en cas de fuite QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Ne touchez à aucun interrupteur ne pas vous servir des téléphones se trouvant dans le bâtiment Appele...

Page 35: ...lle TN 37210 or visit our website at WWW SUPERIORFIREPLACES US COM Innovative Hearth Products IronStrike Brand Gas Fireplaces Stoves and Inserts 20 Year Limited Warranty THE WARRANTY Innovative Hearth Products IHP 20 Year Limited Warranty warrants your IronStrike brand gas fireplace or insert Product to be free from defects in materials and workmanship at the time of manufacture The Product body a...

Page 36: ...our IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The serial number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions concern...

Reviews: