background image

35

12

/02

/20

13

Printed in U.S.A. © 2013  Innovative Hearth Products LLC

P/N 900223-00, Rev. NC  12/2013

Innovative Hearth Products

1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210

Innovative Hearth Products

Superior™ Brand Gas Fireplaces, Stoves and Inserts

20 Year Limited Warranty

THE WARRANTY

Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior™ Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials 

and workmanship at the time of manufacture. The Product body and firebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against 

thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 20 Year Limited 

Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or replacement 

is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also pay IHP prevail-

ing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to five years. THERE ARE EXCLUSIONS AND LIMITATIONS 

to this 20 Year Limited Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of installation. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following 

the date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This 20 Year Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 

instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.

This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 

provided. The Product body and firebox carry the 20 Year Limited Warranty from the date of installation. Vent components, trim components and paint are excluded from 

this 20 Year Limited Warranty. The following do not carry the 20 Year Limited Warranty but are warranted as follows:

Burner

 – Repair or replacement for one year from the date of installation

Gas components

 – Repair or replacement for one year from the date of installation

Gaskets

 – Repair or replacement for one year from the date of installation

Logs

 – Replacement for one year from the date of installation against thermal breakage only

Optional blowers & remote controls

 – Repair or replacement for one year from the date of installation

Optional glass doors 

– Repair or replacement for 90 days from the date of installation

Tempered glass

 - Replacement for one year from the date of installation

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component

Parts not otherwise listed carry a 90 day warranty from the date of installation.

Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either 

natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures 

and could result in a fire hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; 

(d) damages, repairs or inefficiency resulting from faulty installation or application of the Product.

IHP is not responsible for inadequate fireplace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction condi-

tions which may generate negative pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for drafting conditions caused by 

venting configurations, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions that affect the operation of the unit.

This 20 Year Limited Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction, which are not 

manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to 

any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 

or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.

In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or 

after repair or replacement, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a 

particular use or purpose, and there is no implied condition of fitness for a particular use or purpose.

IHP makes no expressed warranties except as stated in this 20 Year Limited Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.

No one is authorized to change this 20 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 

do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this 20 Year 

Limited Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this 20 Year Limited Warranty and to decide, in its sole discretion, upon the method of settlement.

To receive the benefits and advantages described in this 20 Year Limited Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors.

 IHP shall in no event be responsible for any warranty work done by a 

contractor that is not approved without first obtaining IHP's prior written consent.

 

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/

distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 

IHP Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.SUPERIORFIREPLACES.US.COM.

Innovative Hearth Products

IronStrike™ Brand Gas Fireplaces, Stoves and Inserts

20 Year Limited Warranty

THE WARRANTY

Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your IronStrike™ brand gas fireplace or insert ("Product") to be free from defects in materials and 

workmanship at the time of manufacture. The Product body and firebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal 

breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 20 Year Limited Warranty 

period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or replacement is not 

commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also pay IHP prevailing labor 

rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to five years. THERE ARE EXCLUSIONS AND LIMITATIONS to this 20 

Year Limited Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of installation. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the 

date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This 20 Year Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed instruc-

tions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.

This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 

provided. The Product body and firebox carry the 20 Year Limited Warranty from the date of installation. Vent components, trim components and paint are excluded from this 

20 Year Limited Warranty. The following do not carry the 20 Year Limited Warranty but are warranted as follows:

Burner 

– Repair or replacement for one year from the date of installation

Gas components

 – Repair or replacement for one year from the date of installation

Gaskets

 – Repair or replacement for one year from the date of installation

Gold & nickel plating

 – Replacement for two years from date of installation. Excludes tarnishing

Logs

 – Replacement for one year from the date of installation against thermal breakage only

Optional blowers & remote controls

 – Repair or replacement for one year from the date of installation

Optional glass doors

 – Repair or replacement for 90 days from the date of installation

Tempered glass

 – Replacement for one year from the date of installation

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component

Parts not otherwise listed carry a 90 day warranty from the date of installation.

Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either 

natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures and 

could result in a fire hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; (d) 

damages, repairs or inefficiency resulting from faulty installation or application of the Product.

IHP is not responsible for inadequate fireplace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction conditions 

which may generate negative pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for drafting conditions caused by venting 

configurations, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions that affect the operation of the unit.

This 20 Year Limited Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction, which are not 

manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to 

any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, or 

in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.

In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after 

repair or replacement, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a particular 

use or purpose, and there is no implied condition of fitness for a particular use or purpose.

IHP makes no expressed warranties except as stated in this 20 Year Limited Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.

No one is authorized to change this 20 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 

do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this 20 Year 

Limited Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this 20 Year Limited Warranty and to decide, in its sole discretion, upon the method of settlement.

To receive the benefits and advantages described in this 20 Year Limited Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. 

IHP shall in no event be responsible for any warranty work done by a contractor 

that is not approved without first obtaining IHP's prior written consent.

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/

distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP 

Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.IRONSTRIKE.US.COM.

Printed in U.S.A. © 2013  Innovative Hearth Products LLC

P/N 900197-00, Rev. NC  12/2013

Innovative Hearth Products

1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210

Summary of Contents for Ravenna RDV33

Page 1: ...tely Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage...

Page 2: ...ALIENTE CAUSARÁ QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NIÑOS DEBEN NUNCA TOCAR EL VIDRIO L écran pare étincelles fourni avec ce foyer réduit le risque de brûlure en cas de contact accidentel avec la vitre chaude et doit être installé pour la protection Des enfants et Des personnes à risques incluse avec le façade Requis Unabarrera diseñadaparareducirelriesgodequemadurasdesdelamir...

Page 3: ... en funcionamiento Supervise en forma cercana a los niños en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio Mantenga la ropa mobiliario gasolina y otros líquidos inflamables alejados de la chimenea Aún después de haber apagado el gas las superficies de la chimenea permanecen extremadamente calientes Asegúrese de colocar las Etiquetas de advertencia de s...

Page 4: ...kaging List 12 Ratings 12 Insert and Fireplace Dimensions 13 Clearances to Combustibles 14 Insert Leveling 14 Installation 15 17 Venting Installation 15 Zero Clearance Fireplace Installation 16 Firebox Liner Kit required accessory and Log Set Installation 16 Surround Panels Installation required accessory 17 Facade Installation required accessory 17 Gas Line Installation 18 Gas Pressure Requiremen...

Page 5: ...avec la surface chaude Il est recommandé d installer une barrière physique si des personnes à risques habitent la maison Pour empêcher l accès à un foyer ou à un poêle installez une barrière de sécurité cette mesure empêchera les tout petits les jeunes enfants et toute autre personne à risque d avoir accès à la pièce et aux surfaces chaudes 7 Tout écran ou protecteur retiré pour per mettre l entre...

Page 6: ...ndiéndola y apagándola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrola la chimenea Figura A o en el termostato de pared Figura B Seleccione el idioma que más se habla en la casa 2 Si se usa un control remoto para controlar la chimenea encuentre el transmisor y límpielo bien para quitar el polvo y aceite P...

Page 7: ...trôle le fonctionnement du foyer en le faisant basculerdeMarcheàArrêt etvice versa Nettoyez soigneusement la plaque murale de l interrupteur ou le thermostat mural pour éliminer la poussière et les traces de graisse ou d huile Collez l étiquette sur la surface de la plaque de l interrupteur mural qui contrôle le foyer Figure A ou du thermostat mural Figure B Choisissez la langue qui est principale...

Page 8: ...with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes Turn off gas and electrical power to the appliance and allow it to cool before cleaning or servicing the appliance If the barrier becomes damaged the barrier shall be replaced with the manufacturer s barrier for this appliance Si l écran est endommagé il doit être remplacé par celui fournit par le...

Page 9: ...er use solid fuels such as wood paper cardboard coal or any flammable liquids etc in this appliance Plated surfaces must be cleaned with glass cleaner and a clean soft cloth before firing the first time or fingerprints will remain permanently NEVER use brass polish to clean plated surfaces this will remove the plating CAUTION Hot while in operation Do not touch Severe Burns mayresult Keepchildren ...

Page 10: ...225 1 orStandard for Gas Equipped Recreational Vehicles and Mobile Housing CSA Z240 4 Must be vented directly to the outside in accordance with the latest edition of the National Fuel Gas Code and must never be attached to a chimney serving a separate solid fuel burning appliance Has been certified for use with either natural gas or propane Is NOT for use with solid fuels Is approved for sitting r...

Page 11: ... a nationally recognized testing and certification laboratory to ANSI American National Standard Institute gas appliance safety standards This appliance has been tested and certified to ANSI Z21 88 CSA 2 33 Standard for Vented Gas Fireplace Heater and CAN CGA 2 17 M91 and UL 307B Gas Burning Heating Appliances for Manufactured Mobile Homes in both USA and Canada This appliance has met all necessar...

Page 12: ...Contact your IHP dealer for details Packaging List To install your appliance an insert body face surround flange kit and firebox liner kit are required Insert Body Packaging List 1 Insert Body 1 Log Set 1 Bag of Embers 1 Fasteners 6 slotted 1 4 truss screws 6 speed nuts 9 spring clips 3 plastic adhesive wire restraints 1 Installation and Operation Manual Decorative Facade Kits One Required Contemp...

Page 13: ...ions Width of insert behind Surround Panels 31 1 4 794mm Rear height 19 3 4 502mm Insert depth into fireplace 16 406mm Flue collar diameter OD 2 15 16 75mm A B C D Figure 2 Figure 3 Minimum Fireplace Opening A 31 1 2 800mm Front Opening B 19 1 2 495mm Height C 18 457mm Rear Width D 16 406mm Fireplace Depth Top air duct will need to be removed for short ZC applications Replace tap tights when remov...

Page 14: ...Repeat these steps for each adjusting leg Facing and Mantel Clearances Please note that the RDV33 SDVI33 mantel clearances are 4 less than the RDV40 SDVI40 mantel clearances as shown in Figure 4A RDV40 SDVI40 and Figure 4B RDV33 SDVI33 CLEARANCES TO COMBUSTIBLES RDV40 SDVI40 Facing and Mantel Side View RDV33 SDVI33 Facing and Mantel Side View Hearth Protection Figure 4A Figure 5 Clearances Figure ...

Page 15: ...ctural damage or leakage if the fireplace is factory built The appliance may NOT be installed into the fireplace Figure 6b WARNING Direct VentFireplaceInsertVentRequirements Useliner listed to UL181 Factory made Air Ducts And Air Connec tors orUL1777 ChimneyLiners fortheAIRINTAKE Use liner listed to UL1777 ONLY for the EXHAUST Donotsubstitutetheheat ratedflexliner UL1777 forthe exhaustwithanyother...

Page 16: ...au fond de la chambre de combustion Cetorificedoitêtreobturéaumoyend isolantincombustible une fois la conduite de gaz en place The installer must mechanically attach the marking supplied with the gas fireplace insert to the inside of the firebox of the fireplace into which the gas fireplace insert is installed Conversion from Standard 40 000 BTU To Optional 33 000 BTU Input To convert input from 4...

Page 17: ...1 4 truss screws for each side surround panel and secure loosely 5 Fasten the top surround panel with the remaining two truss screws Tighten all six truss screws after adjusting the surround panels to eliminate space between side and top surround panels 6 Assemble the surround trim by inserting the elbowed retainer in the rectangular slot in the ends of the longest piece of trim and secure by tigh...

Page 18: ...ge to valve com ponents Verify that the tanks have step down regulators to reduce the pressure to safe levels LP and Natural Gas Supplies Your gas appliance is equipped from the factory for use with natural gas only as specified on the Safety Listing label attached to the appli ance This appliance can only be operated using propane gas LP if a certified fuel conversion kit provided by IHP is insta...

Page 19: ...LLUSTRATIONS ARE NOT TO SCALE Moving shutter bracket to the right will open shut ter to the left will close shutter Figure 15a Figure 15b SHUTTER ADJUSTMENT DETAIL See Detail Shutter Adjustment Shutter Adjustment Detail ...

Page 20: ...rea for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE INJURY OR LOSS OF LIFE WHAT TO DO IF YOU SMELL GAS DO NOT try to light the appliance DO NOT touch any electric switch do not use any phone in your building Immediately call you...

Page 21: ...pilot is lit turn gas control knob counterclockwise to ON Knob can only be turned to ON if the knob has popped out 11 To turn burner on turn ON OFF rocker switch to ON or set the thermostat to the desired temperature above room temperature 12 Adjust the flame height and heat output by turning the flame height knob clockwise for full flame and counterclock wise for reduced flame 13 Turn on the elec...

Page 22: ... gas valve and orifice may make a rushing or whistling noise If this noise is objectionable it can be reduced by turning down the flame Turning down the flame can reduce total heat output by more than 30 When the blower turns on the sound of rush ing air may be heard The blower sounds may be reduced by adjusting the speed control located on the blower assembly Also a slight clicking sound may be h...

Page 23: ...hes to the appliance for example a rocker switch and a wall thermostat Additional switches may affect the system resistance and increase the chance of the burner not igniting Follow the instructions included with the thermostat or remote control for wiring The thermostat remote control and rocker switch will turn the burner on and off independently Be sure to set the rocker switch to the OFF posi ...

Page 24: ...rubs and plantings that may encroach on the termination o Check gaskets once a year Gaskets must be tight Replace if neces sary o Inspect the pilot system for proper flame NEVER ADJUST THE PILOT untilafterthegaspressurehasbeencheckedandthesupplylineshave been completely bled this may take an hour or more when bleeding through the pilot All pilots are checked and burned at the factory prior to ship...

Page 25: ...mic and alternative types must not be used NOTE BE CAREFUL NOT TO SPRAY COMMERCIAL GLASS CLEANER WITH AMMONIA ON GASKET AREA OF DOOR AM MONIA WILL DISSOLVE GASKET GLUE Glass Door Only doors certified with the appliance shall be used Seules des portes certifiées pour cet appareil doivent être utilisées CAUTION DONOTabuseglassdoorbystrikingorslammingshut Do not remove glass door while the appliance ...

Page 26: ...Pcanbeaccomplished by installing a conversion kit valve regulator and burner orifice Only a qualified service technician should perform the conversion Conversion Kit Please see instructions provided with conver sion kit Blower Removal Unplug the power supply cord from the electrical outlet prior to removing theblower Theblowercanbeaccessedthroughthebackwallofthefirebox Remove the insert face glass...

Page 27: ...Part No J7510 2 Place sight obstructers back over the threaded studs taking note that the upper and lower horizontal bar ends line up with grooves in sight obstructers see Detail A in Figure 22 3 Reinstall the 3 8 nuts 4 Reinstall facade to the unit Cast Pillar Facade see Figure 23 1 Make sure the unit is off and cold 2 Remove the cast pillar facade door from the facade by gripping both sides firm...

Page 28: ...iter and igniter wire Using a match light pilot If pilot lights turn off pilot and trigger the igniter again If pilot lights an intermittent gas air supply may be the problem if longer purge will not light check gap between electrode and pilot should be 1 8 inch 3 mm to have a strong spark If OK replace pilot Pilot will not stay lit after carefully following lighting instructions Low gas inlet pre...

Page 29: ...Speed Control Wire for rheostat H5858 Log Set H5863 Bag of Embers volcanic stone H5864 Bag of Glowing Embers rockwool H3130 Firebox Door w Glass H5989 Hardware Package H5839 Log Set Support H5980 Knob Extension Kit Robertshaw Bay Face H8159 Touch Up Paint Metallic Black 12 oz aerosol J7510 Barrier on Contemporary facade J7511 Barrier on Pillar Cast facade REPLACEMENT PARTS RDV33 40 AND SDVI33 40 C...

Page 30: ...lack ref Form 775208M 75062 GFHKET G Extended Side Trim Gold ref Form 775208M 75063 GFHKET N Extended Side Trim Nickel ref Form 775208M ACCESSORIES RDV33 40 AND SDVI33 40 Tan Brick Red Brick Architectural Stone NOTE The form numbers referenced are the part numbers of the instruction sheets included in kits Product Reference Information Cat No Description Ship Weight Ship Volume H6967 RAV33 40DVI C...

Page 31: ...ickel 33 x 41 75043 GFT3348 N Trim Nickel 33 x 48 Pillar Cast Face Kits u NOTE 3 boxes to complete face 37 5 8 W x 23 3 4 H F2324 PILCST GLASS BARRIER Cast Door Box 1 of 3 ref form 775258M 75092 PILCST PILRS2 Back Pillars Top Box 2 of 3 75094 PILCST GRL TRD3 Grill bars Traditional Box 3 of 3 Or 75091 PILCST GRL FIL3 Grill filigree Ornate Box 3 of 3 45 1 2 1156mm 7 1 8 181mm 30 762mm 22 7 8 581mm u...

Page 32: ...ceiver may be wall mounted or placed in the valve compartment Cost Effective Solution Simple On Off operation Workswithmillivoltandlowvoltageelectronic ignition controls Kit includes Remote and Receiver Wall Thermostat Wall surface mounted Thermostat or manual ON OFF operation Large LCD screen to display room and set temperature in ºF and ºC Connects to wall switch wire Manual or up to 3 hr Countd...

Page 33: ...ERNIÈRE ÉDITION ETATS UNIS OU CAN CGA B149 1 DERNIÈRE ÉDITION CANADA CET APPAREIL DOIT ÊTRE INSTALLÉ SELON LES DIRECTIVES D INSTALLATION DU FABRICANT POUR INSTALLATION DANS DES FOYERS À COMBUSTIBLE SOLIDE SEULEMENT DE MAÇONNERIE OU PRÉFABRIQUÉ EN USINE CE FOYER RADIANT AU GAZ À ÉVACUATION N EST PAS CONÇU POUR ÊTRE UTILISÉ AVEC DES FILTRES À AIR CET APPAREIL DOIT ÊTRE UTILISÉ AVEC LE TYPE DE GAZ IN...

Page 34: ... allumage de la veilleuse B AVANT D ALLUMER L APPAREIL assurez vous qu il n y a pas d odeur de gaz près de l appareil ni près du sol car certains gaz plus lourds que l air auraient tendance à s y accumuler en cas de fuite QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Ne touchez à aucun interrupteur ne pas vous servir des téléphones se trouvant dans le bâtiment Appele...

Page 35: ...lle TN 37210 or visit our website at WWW SUPERIORFIREPLACES US COM Innovative Hearth Products IronStrike Brand Gas Fireplaces Stoves and Inserts 20 Year Limited Warranty THE WARRANTY Innovative Hearth Products IHP 20 Year Limited Warranty warrants your IronStrike brand gas fireplace or insert Product to be free from defects in materials and workmanship at the time of manufacture The Product body a...

Page 36: ...our IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The serial number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions concern...

Reviews: