Turbulator
–
Smoke Pipe Cleaning
a.
Manual Turbulator Cleaning
•
Cover 1 must be closed in Fig. 11.2 when the turbulator is cleaning.
•
Open the top cover number 2 in Fig. 11.2. Move the Turbulator arms number 3
up and down until the turbulators are cleaned.
•
Open covers 1 and 5 in Fig. 11.1.
•
Remove the ashtray number 6 in Fig. 11.1 and clean it.
•
Unscrew the part 1 of Figure 11.2. Clean the ashes from the turbulator.
•
Then close compartment 1 in Fig. 11.2
•
Insert the ashtray.
b.
Automatic Turbulator Cleaning (Optional)
In the smoke pipes, cleaning of the particles caused by the combustion process is
provided automatically.
Every time the boiler is switched off, the system will be activated at the specified
time intervals to perform automatic turbulator cleaning.
Automatic turbulator cleaning will be activated automatically between 08:00- 18:00
every time the boiler is switched off / off.
b.1. Time Switch
ı;
The time switch controls the switching on and off of the circuit at predetermined
intervals in increments of 2 hours for 7 days or 15 minutes for 24 hours.
The time switch is shown in figure 11.3.