4.3.5
Gate Valve
Anticondens should be applied to prevent the heating circulating pump from
being damaged when the valve is closed.
4.3.6
Three Way Mixing Valve
The mixing valve is a mixing valve that brings the hot water from the heating
system to the desired temperature by mixing it with the cooling water in the
heating system.
Features;
• The Kv value should be minimum 30 m³ / h.
•
The pressure loss of the 3-way mixing valve must be a maximum of 0.1 mSS.
• 3
-
way mixing valve outlet diameters must be 1 ¼”
.
The heating circulating pump, the gate valve, the mixing
valve shall be supplied by the user.
4.3.7
Boiler Water Specifications
Properties that should be in boiler water; EN 12953-10
“
Shell boilers- Part 10:
Requirements for feedwater and boiler water quality
”
must comply with the
standard. In the boiler and heating system, water in quality of drink water
should be used in order to prevent damage caused by corrosion. Aggressive
water should not be used for chemical additives because of corrosion. The
water content to be filled in the boiler and the installation must not contain
residues, dirt and undesirable solid particles. These deposits and dirt are
extremely harmful to the circulation pump. If you are suspected that the water
is not clean, necessary precautions should be taken.
Calcified water used in the system forms a lime and mud layer on the heating
surfaces of the boiler. This lime and mud layer prevents water circulation and
heat transfer and deforms the boiler. This is not covered by the warranty.
Summary of Contents for GT-15
Page 1: ...0 2019 PELET KAZANI KULLANMA KILAVUZU PELLET BOILER USERGUIDE Rev No 2019 1 1...
Page 2: ...1...
Page 29: ...28 8 TEMEL PAR ALAR VE BOYUTLAR Model GT 15...
Page 31: ...30 Model GT 25...
Page 33: ...9 BA LANTI EMALARI 9 1 Anakart Model GT 15 GT 25...
Page 74: ...73 8 MAIN PARTS AND DIAMENTIONS Model GT 15...
Page 76: ...75 Model GT 25...
Page 78: ...9 CONNECTION SCHEMAS 9 1 Mainboard Model GT 15 GT 25...
Page 98: ......
Page 99: ......