49
•
Should chimney's pipe inner diameter is 100 mm.
•
Chimney flue test should be performed before making connections. If
the chimney connections should be carried out after removal of the
traction problem had this problem in the chimney.
•
The stove pipe connected to the horizontal flue pipe must not be longer
than 2m. It is recommended to use 45
⁰
elbows in chimney pipes
instead of 90
⁰
bend. (Site selection for stoves should be determined by
the closest point where the chimney.)
•
To avoid turbulence around the chimney flue without any obstructions
(high buildings, trees, etc.) Must be at least 10 m away.
•
The pellets stove should be mounted as close to the chimney as possible
(chimney connection should be short).
•
Chimney cap should be used to prevent the flow into the chimney flue
repercussions of windy weather and rain.
•
Concrete blocks are affected by temperature changes, concrete flat roof
which is in direct contact with the air must be absolutely isolated.
•
An accurate and sufficient flue system for smoke extraction (a chimney
with natural traction (2 Pa - 8 Pa) that does not backfire in the event
of a power outage.)is necessary.
•
Necessary precautions should be taken to prevent condensate formed in
the chimney from reaching the boiler.
•
Clogging or closing of the flue outlet poses a great danger.
Stoves must be connected to a chimney duct which can move vertically
smoke outside the building or its flue pipe to the highest point of the
building.
Chimney connections, if that would be considered illegal in the first
combustion fumes can cause the wall to infiltrate the processing of
these leaks may leave traces. Leaked smoke and / or flames can cause
burns or fire because it can be very hot.
Summary of Contents for GALATA
Page 2: ...1...
Page 25: ...24 8 TEMEL PAR ALAR VE BOYUTLAR Model Galata...
Page 27: ...9 BA LANTI EMALARI 9 1 Anakart...
Page 61: ...60 8 MAIN PARTS AND DIMENSIONS Model Bosphorus...