Technical Data
Measured Values
Device Type /
Model;
Pellet
Stove
BOSPHORUS
Capacity
Nominal heat output
kW
22
Water heating power
kW
14
Ambient heating power
kW
8
Minimum heat output
kW
6,6
Efficiency
Nominal heat output
%
93
Minimum heat output
%
96
Fuel type
Ø 6
/L:30 wood pellet
Fuel consumption (Min.-
Max
.)
1,47 - 4,9
Permissible
operating
temperature
Maximum
⁰
C
80
Minimum
⁰
C
55
Maximum allowable working pressure
bar
3
Test pressure
bar
4,5
Boiler water volume
L
44
Chimney pull required
Pa
12 ± 2
Fuel tank capacity
kg - lt
26 - 43
Weight
Stove
kg
265
Dimensions
(Max X Height X
Height)
Stove
mm
1174x704x876
Oven
mm
364x495x260
Con
ne
ctions
Water Return Connection
inch
1"
Safety drain connection
inch
1/2"
Combustion air inlet connection
mm
Ø 63,5
Chimney connection
(inner
diameter)
mm
Ø 100
Electricity consumption (average)
W
230
Electrical connection
Vac/Hz.
230/50
CO
emission
for
13% O2
Nominal heat output
mg/m3
147,53
Minimum heat output
mg/m3
216,11
Flue gas
temperature
Nominal heat output
⁰
C
125,6
Minimum heat output
⁰
C
88,95