Chapter 4: Web configuration
NS3562-8P-2S-V2 Industrial Managed Switch User Manual
331
The page includes the following fields:
Object
Description
Mode
Enables/disables the per port PD alive check function. All ports
are disabled by default.
Ping PD IP Address
Set the PoE device IP address in this field. The PD
’s IP
address must be set to the same network segment as the
industrial managed switch.
Interval Time (10~300s)
Set the length of time a ping request should be issued to the
PD. Interval time range is from 10 to 300 seconds.
Retry Count (1~5)
Set the number of times that system retry pings to the PD.
For example, if the count is set to 2, and the system retries
pings to the PD and the PD doesn
’t respond continuously, the
PoE port will be reset.
Action
Set the action to be applied if the PD does not respond. Action
selections are as follows:
PD Reboot
: The system resets the PoE port that connected
the PD.
Reboot & Alarm
: The system resets the PoE port and issues
an alarm message via syslog, SMTP.
Alarm
: The system issues an alarm message via syslog,
SMTP.
Reboot Time (30~180s)
Set the PoE device rebooting time. This is useful due to the
different rebooting time of PoE devices. The PD alive check is
not a defining standard, so the PoE device
doesn’t report
reboot complete information to the industrial managed switch.
As a result, the user must ensure how long the PD reboot
takes, and then set the time value in this column.
The system checks the PD again according to the reboot time.
If you cannot determine the precise booting time, we suggest
set it to a longer time.
Buttons
• Click
Save
to save changes.
• Click
Reset
to undo any changes made locally and revert to previously saved
values.