Chapter 4: Web configuration
NS3562-8P-2S-V2 Industrial Managed Switch User Manual
121
Untagged packet entering VLAN 3
1. While [PC-4] an untagged packet enters Port-4, the switch will tag it with a VLAN
Tag=3. [PC-5] and [PC-6] will receive the packet through Port-5 and Port-6.
2. While the packet leaves Port-5, it will be stripped away, becoming an untagged
packet.
3. While the packet leaves Port-6, it will keep as a tagged packet with VLAN Tag=3.
Note:
For this example, set VLAN Group 1 as the default VLAN, but only focus on
VLAN 2 and VLAN 3 traffic flow.
Setup steps
1. Create VLAN group
Set VLAN Group 1 = Default-VLAN with VID (VLAN ID) =1
Add two VLANs
– VLAN 2 and VLAN 3
VLAN Group 2 with VID=2
VLAN Group 3 with VID=3
2. Assign VLAN member:
VLAN 2 : Port-1, Port-2, and Port-3
VLAN 3 : Port-4, Port-5, and Port-6
VLAN 1 : All other ports
– Port-7~Port-24
3. Remove VLAN member for VLAN 1:
Remember to remove Port 1
– Port 6 from VLAN 1 membership, since Port 1 – Port
6 has been assigned to VLAN 2 and VLAN 3.
Note:
It’s important to remove the VLAN members from VLAN 1 configuration,
otherwise the ports will have overlapping setting (see the next VLAN configure sample).
4. Assign PVID to each port:
Port-1, Port-2, and Port-3 : PVID=
2
Port-4, Port-5, and Port-6 : PVID=
3
Port-7~Port-24: PVID=
1
5. Enable VLAN Tag for specific ports
Link Type: Port-3 (VLAN-2) and Port-6 (VLAN-3)