1 Preliminary note

You will find instructions, technical data, approvals and further information using
the QR code on the unit / packaging or at www.ifm.com.

1.1 Symbols used

Requirement

Instructions

Reaction, result

[...]

Designation of keys, buttons or indications

Cross-reference

Important note
Non-compliance may result in malfunction or interference.

Information
Supplementary note

1.2 Warnings used

CAUTION

Warning of personal injury

w

Slight reversible injuries may result.

2 Safety instructions

• The unit described is a subcomponent for integration into a system.

– The system architect is responsible for the safety of the system.

– The system architect undertakes to perform a risk assessment and to create

documentation in accordance with legal and normative requirements to be
provided to the operator and user of the system. This documentation must
contain all necessary information and safety instructions for the operator,
the user and, if applicable, for any service personnel authorised by the
architect of the system.

• Read this document before setting up the product and keep it during the entire

service life.

GB

Summary of Contents for TM48 Series

Page 1: ...Operating instructions Temperature sensor TM48xx TM49xx 80297994 00 12 2020 GB ...

Page 2: ...2 Warnings used 3 2 Safety instructions 3 3 Intended use 4 3 1 Application area 4 4 Installation 4 4 1 Use in hygienic areas according to 3 A 5 4 2 Use in hygienic areas according to EHEDG 5 5 Electrical connection 6 6 Maintenance repair and disposal 7 ...

Page 3: ...ries may result 2 Safety instructions The unit described is a subcomponent for integration into a system The system architect is responsible for the safety of the system The system architect undertakes to perform a risk assessment and to create documentation in accordance with legal and normative requirements to be provided to the operator and user of the system This documentation must contain all...

Page 4: ...intenance of the product must be carried out by qualified personnel authorised by the machine operator Protect units and cables against damage 3 Intended use The unit detects the medium temperature of liquid and gaseous media 3 1 Application area The temperature sensor is used together with a clamp connection in the beverage and food industries 4 Installation CAUTION During installation or in case...

Page 5: ...at have to meet the criteria of E1 2 63 03 of the 3 A standard 63 03 1 3 2 4 5 Fig 1 Installation position for 3 A certification u The positioning of the thermowell sensor must be observed to ensure the mounting adapter will self drain do not install the unit in positions 4 and 5 4 2 Use in hygienic areas according to EHEDG The sensor is suited for CIP clean in place when installed correctly u Obs...

Page 6: ...ead spaces must be possible u Adhere to the dimensions shown in the following figure to avoid dead spaces that cannot be cleaned effectively L D d ØD Ød 6 1 L 3 2 Fig 2 Mounting dimensions for EHEDG approval 1 Sensor 2 Seal in accordance with EHEDG position paper 3 Process connection 5 Electrical connection The unit must be connected by a qualified electrician Voltage supply according to EN50178 S...

Page 7: ...4 BK black 6 Maintenance repair and disposal The operation of the unit is maintenance free Only the manufacturer is allowed to repair the unit u After use dispose of the device in an environmentally friendly way in accordance with the applicable national regulations u Define regular calibration intervals according to the process requirements GB ...

Reviews: