Connect the unit as follows:

4

3

2

1

1
2
3
4

Fig. 3: Wiring diagram (colours in accordance with DIN EN 60947-5-2)

1:

BN (brown)

2:

WH (white)

3:

BU (blue)

4:

BK (black)

6 Maintenance, repair and disposal

The operation of the unit is maintenance-free.

Only the manufacturer is allowed to repair the unit.

u

After use dispose of the device in an environmentally friendly way in
accordance with the applicable national regulations.

u

Define regular calibration intervals according to the process requirements.

GB

Summary of Contents for TM48 Series

Page 1: ...Operating instructions Temperature sensor TM48xx TM49xx 80297994 00 12 2020 GB ...

Page 2: ...2 Warnings used 3 2 Safety instructions 3 3 Intended use 4 3 1 Application area 4 4 Installation 4 4 1 Use in hygienic areas according to 3 A 5 4 2 Use in hygienic areas according to EHEDG 5 5 Electrical connection 6 6 Maintenance repair and disposal 7 ...

Page 3: ...ries may result 2 Safety instructions The unit described is a subcomponent for integration into a system The system architect is responsible for the safety of the system The system architect undertakes to perform a risk assessment and to create documentation in accordance with legal and normative requirements to be provided to the operator and user of the system This documentation must contain all...

Page 4: ...intenance of the product must be carried out by qualified personnel authorised by the machine operator Protect units and cables against damage 3 Intended use The unit detects the medium temperature of liquid and gaseous media 3 1 Application area The temperature sensor is used together with a clamp connection in the beverage and food industries 4 Installation CAUTION During installation or in case...

Page 5: ...at have to meet the criteria of E1 2 63 03 of the 3 A standard 63 03 1 3 2 4 5 Fig 1 Installation position for 3 A certification u The positioning of the thermowell sensor must be observed to ensure the mounting adapter will self drain do not install the unit in positions 4 and 5 4 2 Use in hygienic areas according to EHEDG The sensor is suited for CIP clean in place when installed correctly u Obs...

Page 6: ...ead spaces must be possible u Adhere to the dimensions shown in the following figure to avoid dead spaces that cannot be cleaned effectively L D d ØD Ød 6 1 L 3 2 Fig 2 Mounting dimensions for EHEDG approval 1 Sensor 2 Seal in accordance with EHEDG position paper 3 Process connection 5 Electrical connection The unit must be connected by a qualified electrician Voltage supply according to EN50178 S...

Page 7: ...4 BK black 6 Maintenance repair and disposal The operation of the unit is maintenance free Only the manufacturer is allowed to repair the unit u After use dispose of the device in an environmentally friendly way in accordance with the applicable national regulations u Define regular calibration intervals according to the process requirements GB ...

Reviews: