13
UK
SSC2�1���2�2
Config� Hysteresis
—
n/a (not used)
rSLT
Encoder resolution
Setting of the steps within one
revolution
1... 65535 (16 bits)
rSLF
Encoder resolution
Total revolutions
After reaching rSLF again, the
encoder starts again at "0".
1... 2147482880 (31 bits)
cDir
Counting direction
cw / clockwise
ccw / counter-clockwise
Operating hours
Operating hours counter since
delivery, storage interval one
hour
0��� 1000000 h
Movement
Shaft rotation in hours, storage
interval 15 minutes
0��� 1000000 h
7.2 Application examples
7.2.1 Calculation of the resolution
Total resolution
Resolution per revolution x revolutions = total resolution
4096 x 4096 = 16,777,216
Resolution per revolution (rSLT/16 bits) x resolution number of maximum
revolutions (15 bits) = maximum total resolution (rSLF/ 31 bits)
65,535 x 32,768 = 2,147,450,880