12
7.1 Parameters
The following IO-Link parameters merely provide an overview� A complete
list can be found in the IODD of the unit�
Parameter
Description
Setting range
ou2
Output configuration[OUT 2]
In�D / digital input
SSC1�2
DIx2
Configuration digital input
(pin 2) for counter reset and
counter preset
rSt
pSt
MAVG
Mean value calculation for the
speed filter
10 / 100 / 1000
LED mode
LED display
Communication
Operating voltage
PST
Preset counter value
1��� 2147482880
h�Tim / SSC1�2
Pulse width of the SSC1�2
switching output
OFF
1���100 s
SSC counter
SSC1�1���SSC2�2
Switching signal counter
SSCn�n
0���2147483647
SSC1�1���1�3 Param�
SP1 set point
0���2147483647
SSC1�1���1�3 Param�
SP2 reset point
0���2147483647
SSC1�1���1�3
Config� Logic
NC
NO
Low active
High active
SSC1�1���1�3
Config� Mode
Switch point definition
Single point
Window
SSC1�1���1�3
Config� Hysteresis
—
n/a (not used)
SSC2�1 Param�
SP1/SP2
Setting rotational speed
-119000���120000 rpm
SSC2�1���2�2
Config� Logic
NC
NO
Low active
High active
SSC2�1���2�2
Config� Mode
Switch point definition
Single point
Window