Operating instructions 

Electronic pressure sensor

PN72xx
PN73xx
PN76xx

80285816 / 00

 

07 / 2019

UK

Summary of Contents for PN72 Series

Page 1: ...Operating instructions Electronic pressure sensor PN72xx PN73xx PN76xx 80285816 00 07 2019 UK...

Page 2: ...u 14 8 1 Menu structure main menu 14 8 2 Explanation of the menu 15 8 2 1 Explanation of menu level 1 15 8 2 2 Explanation of menu level 2 15 9 Parameter setting 16 9 1 Parameter setting in general 16...

Page 3: ...ion 27 10 1 Read set parameters 27 10 2 Self diagnostics fault indications 28 11 Technical data 29 11 1 Setting ranges 29 11 1 1 Setting ranges in operating mode 2 29 11 1 2 Setting ranges in operatin...

Page 4: ...e The product must be suitable for the corresponding applications and environmental conditions without any restrictions Only use the product for its intended purpose Functions and features Only use th...

Page 5: ...14 5 1 1 145 10 450 30 Pressure sensors with 1 4 18 NPT PN7670 0 5800 0 400 11580 800 24650 1700 PN7671 0 3625 0 250 7250 500 17400 1200 PN7692 0 1450 0 100 4350 300 9400 650 PN7693 0 362 0 25 2175 1...

Page 6: ...and are designed and manufactured for group 2 fluids in accordance with the sound engineering practice Use of group 1 fluids on request 4 Function The unit displays the current system pressure It gen...

Page 7: ...wing old devices are concerned PN7200 PN7201 PN7202 PN7203 PN7204 PN7206 PN7207 PN7209 PN7300 PN7302 PN7303 PN7304 Applications To ensure compatibility to old devices if sensors are replaced Designati...

Page 8: ...ly granular setting of switch on and switch off points Designation IODD Example PN7294 Status_B High Resolution CMPT 3 At www ifm com in the download area of the corresponding article Manual operating...

Page 9: ...n Window function normally open OUx Fno fig 2 Window function normally closed OUx Fnc fig 2 2 The width of the window can be set by means of the difference between FHx and FLx FHx upper value FLx lowe...

Page 10: ...ware can be found at www ifm com 4 4 2 Functions that are only available via IO Link communication HIPC number of overload processes 9 6 2 HIPS threshold for the overload counter 9 6 2 Flashing The se...

Page 11: ...firmly Recommended tightening torque for 18 NPT thread 2 3 turns after tightening by hand turn further For leak free installation of 18 NPT threads use application specific sealants and lubricants Rec...

Page 12: ...red to Voltage supply according to EN 50178 SELV PELV Disconnect power Connect the unit as follows Core colours 4 3 2 1 BN WH BK BU 4 1 3 2 OUT2 L L OUT1 BK black BN brown BU blue WH white OUT1 switch...

Page 13: ...d LEDs 2 7 System pressure in the indicated unit of measurement 9 Enter button Selection of the parameters and acknowledgement of the parameter values 10 to 11 Arrow keys up and down Setting of the pa...

Page 14: ...14 8 Menu 8 1 Menu structure main menu RUN 1 2 Menu items highlighted in grey e g FH1 are only active when assigned parameters have been selected...

Page 15: ...operating mode 3 ou2 Output function for OUT2 Switching signal for the pressure limits hysteresis function H or window function F as normally open no or normally closed nc each Output off OFF function...

Page 16: ...ue Press to edit the selected parameter Press or for at least 1 s After 1 s setting value is changed incrementally by pressing the button once or continuously by keeping the button pressed Numerical v...

Page 17: ...2 Press to get to the menu Press or until EF is displayed Press The first parameter of the submenu is displayed here rES Change from menu level 1 to menu level 2 when a parameter setting software is...

Page 18: ...rameter setting the unit returns to the operating mode with unchanged values Exit parameter without applying the settings To exit a parameter without applying the settings Press simultaneously Return...

Page 19: ...he selectable units of measurement depend on the respective unit See table with setting ranges 11 1 1 Select diS and set the update rate and orientation of the display d1 update of the measured values...

Page 20: ...mally closed OFF output off Parameter OFF is only available in operating mode 3 CMPT 3 9 4 2 Define switching limits for the hysteresis function ou1 ou2 must be set as Hno or Hnc Select SP1 SP2 and se...

Page 21: ...B Hno Hnc dS dr FH FL A B C D Output function A B C D Fno Fnc dS dr dS dr P system pressure SP set point rP reset point HY hysteresis FE window FH upper value FL lower value If operating mode 1 is use...

Page 22: ...ing range 0 000 4 000 s Damping dAP affects the switch point process data flow IO Link communication and the display 9 5 4 Reset all parameters to factory setting Select rES Press Press or and keep pr...

Page 23: ...measured value is between the limit values of OUT12 and OUT2 r cF display colour red when the measured value is between the freely definable limits cFL and cFH G cF display colour green when the measu...

Page 24: ...play red Measured value switch point OUT1 OUT2 Display green Display colour change for the parameters r1ou r2ou mode window function Display colour change for the parameters G1ou G2ou mode window func...

Page 25: ...r the parameter r 12 mode window function Display colour change for the parameter G 12 mode window function 1 FL1 2 FH1 FL2 FH2 1 FL1 2 FH1 FL2 FH2 Measured value outside FL1 FH1 and FL2 FH2 Display r...

Page 26: ...cFH 1 cFL 2 cFH Measured value between cFL and cFH Display red Measured value between cFL and cFH Display green Colour change display green Colour change display red 1 Initial value of the measuring...

Page 27: ...or at least 0 5 ms HIPS Setting of the threshold for the overload counter The parameters HIPC and HIPS are only available via IO Link communication 10 Operation After power on the unit is in the Run m...

Page 28: ...for short circuit or excessive current Remove the fault SC1 Flashes Flashes F Excessive current at switching output OUT1 Check switching output OUT1 for short circuit or excessive current Remove the f...

Page 29: ...rnal fault malfunction Contact the manufacturer F fault W warning The output remains deactivated as long as the excessive current short circuit continues 11 Technical data 11 1 Setting ranges The sett...

Page 30: ...0 2 36 2 0 2 0 36 2 0 2 0 2 bar 0 01 2 5 0 02 0 2 5 0 02 0 01 kPa 1 250 2 0 250 2 1 PN7297 PN7697 psi 0 05 14 50 0 1 0 14 5 0 1 0 05 mbar 5 1000 5 0 1000 5 5 kPa 0 5 100 0 5 0 100 0 5 0 5 inHg 0 1 29...

Page 31: ...1 2 5 0 02 0 2 5 0 02 0 01 PN7294 PN7694 psi 14 0 145 0 8 14 5 145 0 8 0 1 bar 0 97 10 0 05 1 10 0 05 0 01 MPa 0 097 1 0 005 0 1 1 0 005 0 001 PN7296 PN7696 psi 0 1 36 3 0 2 0 36 3 0 2 0 1 bar 0 01 2...

Page 32: ...W dS1 0 0 dr1 0 0 dS2 0 0 dr2 0 0 P n PnP dAP 0 06 Uni Psi colr rEd diS d2 cFH MEW cFL MAW HIPS MEW CMPT 2 MEW final value of the measuring range MAW initial value of the measuring range The indicated...

Page 33: ...33 UK More information at www ifm com...