6  Electrical connection

The unit must be connected by a qualified electrician.

The national and international regulations for the installation of electrical 

equipment must be adhered to.

Voltage supply to EN50178, SELV, PELV.

 

Disconnect power.

 

Connect the unit as follows:

2 wire connection

3 wire connection


Core colours of ifm sockets:

1 = BN (brown), 2 =  WH (white), 3 =  BU (blue), 4 = BK  (black)

7  Operation

After power on of the supply voltage the unit is in the Run mode (= normal opera-

tion). It carries out its measurement and evaluation functions and provides an 

analogue signal proportional to the system pressure.

7.1  Cleaning of the filter cover

If viscous and residues producing 

media clog the filter cover of the sen-

sor (and thus reduce the measuring 

accuracy slightly), you can clean it.

 

► Unscrew the filter cover (B) (use a 

pair of pliers with plastic-covered 

jaws for this). 

 

Clean the cover thoroughly.

 

The vent (A) should only be cleaned by skilled personnel and with utmost care.

Possible medium residues must not be compressed and pressed into the vent. 

This could clog the filter system and reduce the measuring accuracy of the 

sensor.

Summary of Contents for PL205 Series

Page 1: ...Operating instructions Electronic pressure sensor PL205x 706069 01 06 2019 UK...

Page 2: ...in malfunctions or interference Contents 1 Preliminary note 2 1 1 Symbols used 2 2 Safety instructions 3 3 Functions and features 4 3 1 Applications 4 4 Function 5 4 1 Processing of the measured sign...

Page 3: ...e the product for its intended purpose Functions and features Only use the product for permissible media Technical data If the operating instructions or the technical data are not adhered to personal...

Page 4: ...145 50 725 150 2 175 PL2056 0 13 2 5 1 8 36 3 20 290 50 725 mbar PSI bar PSI bar PSI PL2057 50 1 000 0 7 14 5 10 145 30 450 mbar inH2O bar inH2O bar inH2O PL2058 12 5 250 5 0 100 4 6 2400 30 12 000 MP...

Page 5: ...tting the parameter AEP you define the measured value at which the output signal is 20 mA Factory setting Measuring range scaled P system pressure MEW final value of the measuring range The output sig...

Page 6: ...flange or similar A to the process connec tion If it is not possible to slide the fixing element A down over the top of the sensor slide it up over the bottom of the sensor before the adapter is mount...

Page 7: ...r using a spanner until you can feel the end stop cor responding to a maximum tighten ing torque of 25 Nm 18 ftlb Note Do not overtighten This can have an adverse effect on the sealing NOTE A guarante...

Page 8: ...mal opera tion It carries out its measurement and evaluation functions and provides an analogue signal proportional to the system pressure 7 1 Cleaning of the filter cover If viscous and residues prod...

Page 9: ...ween ASP and AEP 25 of the span HI LO Min Max memory for system pressure HI displays the highest measured pressure LO displays the lowest measured pressure COF Calibration offset The internal measured...

Page 10: ...L2053 bar 1 0 18 8 5 3 25 0 0 1 PSI 15 272 76 363 1 MPa 0 10 1 88 0 53 2 50 0 01 PL2054 bar 0 50 7 49 2 00 9 99 0 01 PSI 7 109 29 145 1 kPa 50 749 200 999 1 PL2056 bar 0 13 1 88 0 50 2 50 0 01 PSI 1 8...

Page 11: ...11 UK More information at www ifm com...

Reviews: