5 Installation
Ensure that no pressure is applied to the installation while mounting or
removing the sensor.
Aseptoflex adapters ensure that the
sensor can be connected to different
process connections.
(The adapters have to be ordered
separately as accessories.)
Mounting operation
:
► Mount the adapter (B) to the sen
-
sor.
►
Fix adapter by means of
a coupling nut, a clamp flange or
similar (A) to the process connec
-
tion.
If it is not possible to slide the fixing
element (A) down over the top of the
sensor: slide it up over the bottom
of the sensor before the adapter is
mounted.
Mounting the Aseptoflex adapter
►
Slightly grease the threads and
sealing areas of the sensor and
adapter with lubricating paste (1).
The paste must be suitable and
approved for the application and
compatible with the elastomers
used.
Recommendation: Klüber paste
UH1 84-201 with USDA-H1 ap-
proval for the food industry.
► Make sure that the O-ring (C) is
correctly positioned.
1