2  Safety instructions

•  The device described is a subcomponent for integration into a system.

 -The manufacturer of the system is responsible for the safety of the system.

 -The system manufacturer undertakes to perform a risk assessment and to 

create a documentation in accordance with legal and normative requirements 

to be provided to the operator and user of the system. This documentation 

must contain all necessary information and safety instructions for the opera-

tor, the user and, if applicable, for any service personnel authorised by the 

manufacturer of the system.

•  Read this document before setting up the product and keep it during the entire 

service life.

•  The product must be suitable for the corresponding applications and environ-

mental conditions without any restrictions.

• 

Only use the product for its intended purpose (→ Functions and features).

• 

Only use the product for permissible media (→ Technical data). 

•  If the operating instructions or the technical data are not adhered to, personal 

injury and/or damage to property may occur.  

•  The manufacturer assumes no liability or warranty for any consequences 

caused by tampering with the product or incorrect use by the operator.

•  Installation, electrical connection, set-up, operation and maintenance of the unit 

must be carried out by qualified personnel authorised by the machine operator.

•  Protect units and cables against damage.
For the scope of validity cULus: The device shall be supplied from an isolating 

transformer having a secondary Listed fuse rated as noted in the following table.

Overcurrent protection

Control-circuit wire size

Maximum protective device rating 

Ampere

AWG

(mm

2

)

26

(0.13)

1

24

(0.20)

2

22

(0.32)

3

20

(0.52)

5

18

(0.82)

7

16

(1.3)

10

The Sensor shall be connected only by using any R/C (CYJV2) cord, having suit

-

able ratings.

Summary of Contents for PL205 Series

Page 1: ...Operating instructions Electronic pressure sensor PL205x 706069 01 06 2019 UK...

Page 2: ...in malfunctions or interference Contents 1 Preliminary note 2 1 1 Symbols used 2 2 Safety instructions 3 3 Functions and features 4 3 1 Applications 4 4 Function 5 4 1 Processing of the measured sign...

Page 3: ...e the product for its intended purpose Functions and features Only use the product for permissible media Technical data If the operating instructions or the technical data are not adhered to personal...

Page 4: ...145 50 725 150 2 175 PL2056 0 13 2 5 1 8 36 3 20 290 50 725 mbar PSI bar PSI bar PSI PL2057 50 1 000 0 7 14 5 10 145 30 450 mbar inH2O bar inH2O bar inH2O PL2058 12 5 250 5 0 100 4 6 2400 30 12 000 MP...

Page 5: ...tting the parameter AEP you define the measured value at which the output signal is 20 mA Factory setting Measuring range scaled P system pressure MEW final value of the measuring range The output sig...

Page 6: ...flange or similar A to the process connec tion If it is not possible to slide the fixing element A down over the top of the sensor slide it up over the bottom of the sensor before the adapter is mount...

Page 7: ...r using a spanner until you can feel the end stop cor responding to a maximum tighten ing torque of 25 Nm 18 ftlb Note Do not overtighten This can have an adverse effect on the sealing NOTE A guarante...

Page 8: ...mal opera tion It carries out its measurement and evaluation functions and provides an analogue signal proportional to the system pressure 7 1 Cleaning of the filter cover If viscous and residues prod...

Page 9: ...ween ASP and AEP 25 of the span HI LO Min Max memory for system pressure HI displays the highest measured pressure LO displays the lowest measured pressure COF Calibration offset The internal measured...

Page 10: ...L2053 bar 1 0 18 8 5 3 25 0 0 1 PSI 15 272 76 363 1 MPa 0 10 1 88 0 53 2 50 0 01 PL2054 bar 0 50 7 49 2 00 9 99 0 01 PSI 7 109 29 145 1 kPa 50 749 200 999 1 PL2056 bar 0 13 1 88 0 50 2 50 0 01 PSI 1 8...

Page 11: ...11 UK More information at www ifm com...

Reviews: