21
UK
8 Operating modes
The different operating modes of the safety light curtains of the OY series can be
set via the respective connections to the 8-pole plug of the receiver�
Operating modes
Connections
pin 4
pin 5
pin 6
A
Automatic
K1_K2 /restart
Connects to:
L+ (24 V DC)
SEL_A
Connects to:
L+ (24 V DC)
SEL_B
Connects to:
L- (0 V DC)
6
4
8
5
L+ L
B
Automatic with monitoring
K1_K2
K1_K2 /restart
Connects to:
L+ (24 V DC)
(via NC contacts
of K1_K2)
SEL_A
Connects to:
L+ (24 V DC)
SEL_B
Connects to:
L- (0 V DC)
6
4
8
5
L+ L
C
Manual
K1_K2 /restart
Connects to:
L+ (24 V DC)
(via start button)
SEL_A
Connects to:
L- (0 V DC)
SEL_B
Connects to:
L+ (24 V DC)
5
4
8
6
L+ L
D
Manually with monitoring K1_K2 K1_K2 /restart
Connects to:
L+ (24 V DC)
(via start button
and NC contacts
of K1_K2)
SEL_A
Connects to:
L- (0 V DC)
SEL_B
Connects to:
L+ (24 V DC)
5
4
8
6
L+ L
1: K1
2: K2
3: Restart