OPD101
17
8 Set-up
u
After installation, electrical connection and programming, check whether the unit operates correctly.
w
If the unit has been correctly set up, the sensor starts with the “Guided Teach”. “Guided Teach” /
teaching of reference profiles (
18). The settings made last are internally stored by the
sensor.
When the sensor is switched on for the first time after a reset, it will also start with the “Guided
Teach” as the taught reference profile is deleted in case of a reset.
Lifetime of a laser diode: 50000 hours.
After successful teaching, the sensor should not be moved again. Any change of the sensor
position will lead to the activated reference profile not being recognised reliably.
The sensor must be taught again if it has been moved.
The sensor needs a warm-up period of ≥ 10 min. The performance parameters specified in the
data sheet only apply after this warm-up period.
The teaching of objects should also be done in the warmed-up state.
GB